▮▮Coloprice

Sungrow · 公用事业级

Sungrow PowerTitan 2.0

供货中

20 英尺集装箱交流模块(PCS 集成)liquid-cooledLFP · 314 AhBNEF Tier I

以下所有信息来自 Sungrow 关于 PowerTitan 2.0 的公开发布内容:数据表、产品页面和新闻稿。如果某项数据未公开发布,该字段会标注——我们不进行任何估算。

示意图—非制造商照片

规格型号

5.015 MWh

功率: 2.52 MW

已验证 2026-08

规格型号

能量数据按 标称值(初期生命周期) 发布,由制造商公开。同一产品,多种时长选项 — 相同外壳,不同功率等级。

规格型号能量功率时长
ST5015UX-2H (210 kVA x 12)5.015 MWh2.52 MW2 h
ST5015UX-3H5.015 MWh1.524 MW3 h
ST5015UX-4H (210 kVA x 6)5.015 MWh1.26 MW4 h
ST5015UX-4H-HT (high-temperature, -5…55 °C, no derating to 55 °C)5.015 MWh1.26 MW4 h
ST5015UX-6H5.015 MWh762 kW6 h
ST5015UX-2H-US (60 Hz, Type 3S)5.015 MWh2.52 MW2 h
ST5015UX-4H-US (60 Hz, Type 3S)5.015 MWh1.26 MW4 h
ST5015UX-6H-US5.015 MWh762 kW6 h
ST5015UX-8H-US (product page lists 762 kVA, apparently copied from 6H; no datasheet)5.015 MWh未公开8 h
ST5015UX-S-2H / -S-2H-AU (DC variant, external SC4980/6900UD-MV PCS)5.015 MWh未公开2 h
ST5015UX-S-4H / -S-4H-AU (DC variant, external SC4980/6900UD-MV PCS)5.015 MWh未公开4 h

规格参数

电芯化学LFP
电芯容量314 Ah
电芯配置416S12P
电芯供应商未公开
形态20 英尺集装箱
模块类型交流模块(PCS 集成)
PCS 集成
直流电压1123.2–1497.6 V
散热liquid-cooled
防护等级IP55
Operating temperature-30…50 (derating >45) °C
尺寸(长 × 宽 × 高)6058 × 2438 × 2896 mm
重量42 t
能量密度未公开
Round-trip efficiency89.5%
循环寿命未公开
日历寿命20 y
保修期未公开
灭火系统FK5112 clean agent (default) with FACP, flammable-gas/smoke/heat detectors, sounder beacon, ventilation, pressure relief port; optional sprinkler, vent panel, aerosol. US variant: NFPA 68 vent panel, smoke/heat detectors, Mini FACP (default); optional sprinkler, NFPA 69 ventilation, flammable gas detector
2.0
发布2023-06

Certifications

IEC61000IEC62619IEC62933AS3000UKCAG99UN38.3/UN3536CEIEC62477UL 9540ANFPA 855NFPA 68NFPA 69 ( optional )IEEE 1547UL 1973UL 1741SBUL 9540

核心参数

  • 2.5 MW / 5 MWh AC block: 314 Ah LFP cells (416S12P, 5,015 kWh) plus 12 x 210 kVA string PCS in a 20 ft container; 4-h SKU uses 6 x 210 kVA
  • Weight 42,000 kg (2H) / 42,500 kg (4H); 6058 x 2896 x 2438 mm; IP55, C3 (C4 on US SKU); 4,000 m altitude (3,000 m US)
  • Press release (Intersolar 2023): RTE 89.5%, '20-year system performance life', auxiliary consumption 50 kWh/day, cell temperature spread 2.5 °C
  • US datasheet: 60 Hz, Type 3S, UL 9540 / UL 9540A / UL 1973 / UL 1741SB / NFPA 855; ST5015UX-4H-HT operates without derating up to 55 °C
  • '-S' SKUs (ST5015UX-S-2H/-4H, AU) are DC-coupled versions paired with external SC4980/6900UD-MV central PCS; separate 3H, 6H and 8H-US pages carry no datasheets
  • Cell supplier, cycle life, DC round-trip efficiency and warranty are not published

此型号 Sungrow 未公开的规格

这些字段为空,是因为没有公开的数据表或发布文档说明它们。这本身也是信息:在列入候选前,请务必询问这些参数。

电芯供应商能量密度循环寿命保修期

价格参考

$90–130/kWh

Estimate, not an offer. Important: PowerTitan 2.0 is an AC block with a built-in 2.5 MW PCS, so comparing it against bare DC-container prices ($71–89 FOB) is apples-to-oranges — PCS integration adds roughly $15–40/kWh. Range is ex-works China; installed EU/US projects on PowerTitan land at $150–300+/kWh turnkey.

来自 Coloprice BESS 价格指数 — 基准数据,非报价。查看该指数了解各数据的收集方式。 查看 BESS 价格指数 →

其他制造商的同类产品

Sungrow PowerTitan 2.0 采购询价

Coloprice 由 Dream View(一家中国采购公司)运营。对于商业规模的项目,我们从工厂直接采购 BESS 容器 — 制造商验证、认证审核、发货前检验、出口和运费 — 服务费为固定 10%。

我们在一个工作日内回复。无垃圾邮件,不转售您的联系方式。

来源: Sungrow — PowerTitan 2.0 product page · Sungrow — ST5015UX-2H product page · Datasheet ST5015kWh-2500kW-2h / 1250kW-4h (PDF) · Sungrow — ST5015UX-4H-US product page · Datasheet ST5015UX-2H-US / 4H-US (PDF) · Sungrow — ST5015UX-S-4H product page (DC variant) · Press release: Sungrow Releases PowerTitan 2.0 (2023-06-14)