▮▮Coloprice

储能对比

CATL TENER vs Huawei Digital Power LUNA2000-5015-2S

两列数据均来自 CATL 和 Huawei Digital Power 的公开发布。生产商未公开的字段标记为「未公开」;我们不进行估算或排名。

规格参数对比

字段CATL TENERHuawei Digital Power LUNA2000-5015-2S
单机柜最大能量6.25 MWh5.015 MWh
单机柜最大功率3.126 MW2.508 MW
放电时长2 h2 h
分类公用事业级公用事业级
状态供货中供货中
电芯化学LFPLFP
电芯容量587 Ah314 Ah
电芯配置1P104S×4×8P (pack 1P104S, 4 packs per rack = 1P416S, 8 racks in parallel)2P104S per pack (104 cells, 2×314 Ah); container-level configuration not published
电芯供应商未公开未公开
形态20 英尺集装箱20 英尺集装箱
模块类型直流模块直流模块
PCS 集成
直流电压1331.2 rated; 1040–1500 range V1331.2 rated / 1500 max V
散热liquid-cooledliquid-cooled
防护等级未公开IP55
Operating temperature-30…55 °C-30…55 °C
尺寸(长 × 宽 × 高)未公开6058 × 2438 × 2896 mm
重量45 t43 t
能量密度未公开未公开
Round-trip efficiency未公开未公开
循环寿命8,000 · Cell-level figure from CATL 2026 brochure: 587 Ah cell ≥8,000 cycles (25 °C, 0.5P/0.5P, 70% SOH). System-level cycle life not published; CATL claims zero capacity/power degradation in first five years.未公开
日历寿命未公开未公开
保修期未公开未公开
灭火系统未公开water sprinkler + NOVEC 1230
TENER (2024); Chinese market designation 天恒 C2-L6252025
发布2024-042025-05
CertificationsGB 44240-2024, GB/T 34131-2023, GB/T 36276-2023, GB/T 44026-2024IEC 61000-6-2, IEC 62040-1, IEC 62477-1, IEC 62619, IEC 62933-5-2, RoHS, UL 9540A, UN 38.3
公开数据表

差异对比

仅显示两家生产商均已公开且数值不同的字段。这不是评判——最佳选择取决于项目需求。

  • 单机柜最大能量: TENER — 6.25 MWh; LUNA2000-5015-2S — 5.015 MWh
  • 单机柜最大功率: TENER — 3.126 MW; LUNA2000-5015-2S — 2.508 MW
  • 电芯容量: TENER — 587 Ah; LUNA2000-5015-2S — 314 Ah
  • 电芯配置: TENER — 1P104S×4×8P (pack 1P104S, 4 packs per rack = 1P416S, 8 racks in parallel); LUNA2000-5015-2S — 2P104S per pack (104 cells, 2×314 Ah); container-level configuration not published
  • 直流电压: TENER — 1331.2 rated; 1040–1500 range V; LUNA2000-5015-2S — 1331.2 rated / 1500 max V
  • 重量: TENER — 45 t; LUNA2000-5015-2S — 43 t
  • : TENER — TENER (2024); Chinese market designation 天恒 C2-L625; LUNA2000-5015-2S — 2025
  • 发布: TENER — 2024-04; LUNA2000-5015-2S — 2025-05
  • Certifications: TENER — GB 44240-2024, GB/T 34131-2023, GB/T 36276-2023, GB/T 44026-2024; LUNA2000-5015-2S — IEC 61000-6-2, IEC 62040-1, IEC 62477-1, IEC 62619, IEC 62933-5-2, RoHS, UL 9540A, UN 38.3

仅由其中一家发布:防护等级, 尺寸(长 × 宽 × 高), 循环寿命, 灭火系统。

变体

CATL TENER 变体

规格型号能量功率时长
6.25 MWh 0.5P (2 × 1562.82 kW); brochure states 2 h/4 h system compatibility6.25 MWh3.126 MW2 h

Huawei Digital Power LUNA2000-5015-2S 变体

规格型号能量功率时长
5,015 kWh / 2,507.5 kW (≤ 0.5 CP)5.015 MWh2.508 MW2 h

完整产品卡片

查看 CATL TENER →查看 Huawei Digital Power LUNA2000-5015-2S →

其他对比

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CATL TENERGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Huawei Digital Power LUNA2000-5015-2SPylontech Container L5000-BAT vs CATL TENERPylontech Container L5000-BAT vs Huawei Digital Power LUNA2000-5015-2SSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CATL TENERSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs Huawei Digital Power LUNA2000-5015-2SCATL TENER vs Great Power Max-20HC-5000CATL TENER vs HiTHIUM ∞Power 6.25MWh