储能对比
LG Energy Solution JF2 AC LINK (2HR / 4HR) vs Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2)
两列数据均来自 LG Energy Solution 和 Sunwoda Energy 的公开发布。生产商未公开的字段标记为「未公开」;我们不进行估算或排名。
LG Energy Solution
JF2 AC LINK (2HR / 4HR)
5.11 MWh
模块化liquid-cooledLFP供货中
Sunwoda Energy
NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2)
5.015 MWh
20 英尺集装箱liquid-cooledLFP供货中
规格参数对比
| 字段 | LG Energy Solution JF2 AC LINK (2HR / 4HR) | Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) |
|---|---|---|
| 单机柜最大能量 | 5.11 MWh | 5.015 MWh |
| 单机柜最大功率 | 2.55 MW | 2.508 MW |
| 放电时长 | 2 h · 4 h | 2 h |
| 分类 | 公用事业级 | 公用事业级 |
| 状态 | 供货中 | 供货中 |
| 电芯化学 | LFP | LFP |
| 电芯容量 | 未公开 | 314 Ah |
| 电芯配置 | 14 packs in series × 6 racks in parallel (2HR) | 4170 kWh: 1P104S packs (104.49 kWh), 1P416S racks (417 kWh) x10; 5015 kWh: 12P416S |
| 电芯供应商 | 未公开 | 未公开 |
| 形态 | 模块化 | 20 英尺集装箱 |
| 模块类型 | 交流模块(PCS 集成) | 直流模块 |
| PCS 集成 | 是 | 否 |
| 直流电压 | 未公开 | 4170: 1164.8–1497.6 (rated 1331.2); 5015: 1040–1500 (nominal 1331.2) V |
| 散热 | liquid-cooled | liquid-cooled |
| 防护等级 | IP55 | IP55 / NEMA 3R |
| Operating temperature | -30…50 °C | 4170: -30…60; 5015: -30…55 °C |
| 尺寸(长 × 宽 × 高) | 7020 × 2570 × 2900 mm | 6058 × 2438 × 2896 mm |
| 重量 | 48 t | 41 t |
| 能量密度 | 未公开 | 未公开 |
| Round-trip efficiency | 未公开 | 93% |
| 循环寿命 | 未公开 | 10,000 · Brochure (2023-11) for 314 Ah cell / NoahX-1500/4170: '10000 cycles @25℃, 0.5CP/0.5CP'. Press release (2023-09) claims cell cycle life 'exceeding 12,000 cycles' and product page for the 314 Ah cell lists 12000 cycles |
| 日历寿命 | 未公开 | 20 y |
| 保修期 | 未公开 | 未公开 |
| 灭火系统 | gas detection and active venting system, fire detection and alarm system | Water FSS / aerosol (optional); pack-level fire suppression, combustible gas emission and explosion venting (press release) |
| 代 | 2024 | NoahX 2.0, 2023 |
| 发布 | 2024-11 | 2023-09 |
| Certifications | IEEE1547, IFC/CFC, NFPA 69, NFPA 72, NFPA 855, UL1642, UL1741 (SA, SB), UL1973, UL9540, UL9540A and large-scale fire testing, UN 38.3 | AS3000, GB36276, IEC61000, IEC62477, IEC62619, IEC62933, NFPA68/69, NFPA855, UL1973, UL9540A, UN3536, UN38.3 |
| 公开数据表 | 是 | 是 |
差异对比
仅显示两家生产商均已公开且数值不同的字段。这不是评判——最佳选择取决于项目需求。
- 单机柜最大能量: JF2 AC LINK (2HR / 4HR) — 5.11 MWh; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 5.015 MWh
- 单机柜最大功率: JF2 AC LINK (2HR / 4HR) — 2.55 MW; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 2.508 MW
- 放电时长: JF2 AC LINK (2HR / 4HR) — 2 h · 4 h; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 2 h
- 电芯配置: JF2 AC LINK (2HR / 4HR) — 14 packs in series × 6 racks in parallel (2HR); NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 4170 kWh: 1P104S packs (104.49 kWh), 1P416S racks (417 kWh) x10; 5015 kWh: 12P416S
- 形态: JF2 AC LINK (2HR / 4HR) — 模块化; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 20 英尺集装箱
- 模块类型: JF2 AC LINK (2HR / 4HR) — 交流模块(PCS 集成); NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 直流模块
- PCS 集成: JF2 AC LINK (2HR / 4HR) — 是; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 否
- 防护等级: JF2 AC LINK (2HR / 4HR) — IP55; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — IP55 / NEMA 3R
- Operating temperature: JF2 AC LINK (2HR / 4HR) — -30…50 °C; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 4170: -30…60; 5015: -30…55 °C
- 尺寸(长 × 宽 × 高): JF2 AC LINK (2HR / 4HR) — 7020 × 2570 × 2900 mm; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 6058 × 2438 × 2896 mm
- 重量: JF2 AC LINK (2HR / 4HR) — 48 t; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 41 t
- 灭火系统: JF2 AC LINK (2HR / 4HR) — gas detection and active venting system, fire detection and alarm system; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — Water FSS / aerosol (optional); pack-level fire suppression, combustible gas emission and explosion venting (press release)
- 代: JF2 AC LINK (2HR / 4HR) — 2024; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — NoahX 2.0, 2023
- 发布: JF2 AC LINK (2HR / 4HR) — 2024-11; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 2023-09
- Certifications: JF2 AC LINK (2HR / 4HR) — IEEE1547, IFC/CFC, NFPA 69, NFPA 72, NFPA 855, UL1642, UL1741 (SA, SB), UL1973, UL9540, UL9540A and large-scale fire testing, UN 38.3; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — AS3000, GB36276, IEC61000, IEC62477, IEC62619, IEC62933, NFPA68/69, NFPA855, UL1973, UL9540A, UN3536, UN38.3
仅由其中一家发布:电芯容量, 直流电压, Round-trip efficiency, 循环寿命, 日历寿命。
变体
LG Energy Solution JF2 AC LINK (2HR / 4HR) 变体
| 规格型号 | 能量 | 功率 | 时长 |
|---|---|---|---|
| JF2 2HR AC LINK — 5.11 MWh / 2.55 MW, 690 Vrms, 0.5 CP | 5.11 MWh | 2.55 MW | 2 h |
| JF2 4HR AC LINK — 5.11 MWh / 1.32 MW (6 × 220 kVA), 690 Vrms, 0.25 CP | 5.11 MWh | 1.32 MW | 4 h |
Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) 变体
| 规格型号 | 能量 | 功率 | 时长 |
|---|---|---|---|
| NoahX-1500/4170 — 4170 kWh, rated 0.5CP (2085 kW derived from published C-rate) | 4.17 MWh | 2.085 MW | 2 h |
| NoahX-1500/5015-L2 — 5015 kWh, standard 0.5P (2508 kW derived from published C-rate) | 5.015 MWh | 2.508 MW | 2 h |
完整产品卡片
查看 LG Energy Solution JF2 AC LINK (2HR / 4HR) →查看 Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) →
其他对比
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs LG Energy Solution JF2 AC LINK (2HR / 4HR)Pylontech Container L5000-BAT vs Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2)Pylontech Container L5000-BAT vs LG Energy Solution JF2 AC LINK (2HR / 4HR)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CATL TENERSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs Great Power Max-20HC-5000Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs HiTHIUM ∞Power 6.25MWhSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs ZOE Energy Storage Z BOX-P 6200 2H