▮▮Coloprice

储能对比

AlphaESS Aster 5000 vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System

两列数据均来自 AlphaESS 和 CRRC Zhuzhou Institute 的公开发布。生产商未公开的字段标记为「未公开」;我们不进行估算或排名。

规格参数对比

字段AlphaESS Aster 5000CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System
单机柜最大能量5.016 MWh6.901 MWh
单机柜最大功率2.508 MW未公开
放电时长2 h2 h · 4 h
分类公用事业级公用事业级
状态供货中供货中
电芯化学LFPLFP
电芯容量未公开587 Ah
电芯配置未公开416S4P (10-ft) / 416S8P (20-ft)
电芯供应商未公开未公开
形态20 英尺集装箱20 英尺集装箱
模块类型直流模块直流模块
PCS 集成
直流电压1331.2 (rated) V1081.6–1497.6 V
散热liquid-cooledliquid-cooled
防护等级IP55IP55
Operating temperature-40…50 (battery module) °C-30…55 °C
尺寸(长 × 宽 × 高)6058 × 2438 × 2896 mm6058 × 2438 × 2896 mm
重量43 t48 t
能量密度未公开未公开
Round-trip efficiency未公开未公开
循环寿命未公开未公开
日历寿命未公开未公开
保修期未公开未公开
灭火系统aerosol + sprinkler (redundant dual-extinguishing) + explosion relief panelAerosol-based suppression system; flooded fire protection systems (options); fire alarm panel, heat and smoke detection, alarm bell and strobe
V01 (2025-05)6.X (2026)
发布未公开2026-01
CertificationsIEC 61000, IEC 62477, IEC 62619, IEC 62933, NFPA 69, UL 1973, UL 9540AIEC 61000, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL9540A, UN3536, UN38.3
公开数据表

差异对比

仅显示两家生产商均已公开且数值不同的字段。这不是评判——最佳选择取决于项目需求。

  • 单机柜最大能量: Aster 5000 — 5.016 MWh; 6.X Liquid Cooling Energy Storage System — 6.901 MWh
  • 放电时长: Aster 5000 — 2 h; 6.X Liquid Cooling Energy Storage System — 2 h · 4 h
  • 直流电压: Aster 5000 — 1331.2 (rated) V; 6.X Liquid Cooling Energy Storage System — 1081.6–1497.6 V
  • Operating temperature: Aster 5000 — -40…50 (battery module) °C; 6.X Liquid Cooling Energy Storage System — -30…55 °C
  • 重量: Aster 5000 — 43 t; 6.X Liquid Cooling Energy Storage System — 48 t
  • 灭火系统: Aster 5000 — aerosol + sprinkler (redundant dual-extinguishing) + explosion relief panel; 6.X Liquid Cooling Energy Storage System — Aerosol-based suppression system; flooded fire protection systems (options); fire alarm panel, heat and smoke detection, alarm bell and strobe
  • : Aster 5000 — V01 (2025-05); 6.X Liquid Cooling Energy Storage System — 6.X (2026)
  • Certifications: Aster 5000 — IEC 61000, IEC 62477, IEC 62619, IEC 62933, NFPA 69, UL 1973, UL 9540A; 6.X Liquid Cooling Energy Storage System — IEC 61000, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL9540A, UN3536, UN38.3

仅由其中一家发布:单机柜最大功率, 电芯容量, 电芯配置, 发布。

变体

AlphaESS Aster 5000 变体

规格型号能量功率时长
Aster 5000 (AlphaCS-H20-DC-LC-EX, 12 clusters, 0.5 P)5.016 MWh2.508 MW2 h

CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System 变体

规格型号能量功率时长
CESS-L3125-EU-0.5C — 3.125 MWh (10-ft, 587 Ah)3.125 MWh未公开2 h
CESS-L3125-EU-0.25C — 3.125 MWh (10-ft, 587 Ah)3.125 MWh未公开4 h
CESS-L3450-EU-0.5C — 3.450 MWh (10-ft, 648 Ah)3.45 MWh未公开2 h
CESS-L6250-EU-0.5C — 6.250 MWh (20-ft, 587 Ah)6.25 MWh未公开2 h
CESS-L6250-EU-0.25C — 6.250 MWh (20-ft, 587 Ah)6.25 MWh未公开4 h
CESS-L6901-EU-0.5C — 6.901 MWh (20-ft, 648 Ah)6.901 MWh未公开2 h

完整产品卡片

查看 AlphaESS Aster 5000 →查看 CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System →

其他对比

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs AlphaESS Aster 5000Pylontech Container L5000-BAT vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemPylontech Container L5000-BAT vs AlphaESS Aster 5000Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs AlphaESS Aster 5000CATL TENER vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemCATL TENER vs AlphaESS Aster 5000