规格参数对比

字段CLOU Electronics Aqua-C3.0 (S/H Version)Huawei Digital Power LUNA2000-5015-2S
单机柜最大能量6.251 MWh5.015 MWh
单机柜最大功率3.125 MW2.508 MW
放电时长2 h · 4 h2 h
分类公用事业级公用事业级
状态供货中供货中
电芯化学LFPLFP
电芯容量587 Ah314 Ah
电芯配置1P416S×8 (8P416S)2P104S per pack (104 cells, 2×314 Ah); container-level configuration not published
电芯供应商未公开未公开
形态20 英尺集装箱20 英尺集装箱
模块类型交流模块(PCS 集成)直流模块
PCS 集成
直流电压1123.2–1497.6 V1331.2 rated / 1500 max V
散热liquid-cooledliquid-cooled
防护等级IP55IP55
Operating temperature-30…50 (55 optional on H) °C-30…55 °C
尺寸(长 × 宽 × 高)6058 × 2438 × 2896 mm6058 × 2438 × 2896 mm
重量47 t43 t
能量密度未公开未公开
Round-trip efficiency未公开未公开
循环寿命未公开未公开
日历寿命未公开未公开
保修期未公开未公开
灭火系统smoke/heat detectors, FACP, ventilation (NFPA 69), dry pipes with sprinklers, aerosol (optional on S), deflagration vent panel (optional)water sprinkler + NOVEC 1230
3.02025
发布2025-062025-05
CertificationsCE, CEI 0-16, EN 50549, EN 62477-1, G99, IEC 61000, IEC 62477-1, IEC 62619, IEC 62933, IEC 62993-5-2, IEC 63056, NTS 2.1, NTS SENP 1.1, UL 9540A, UN 38.3/UN 3536, VDE-AR-N 4110, VDE-AR-N 4120IEC 61000-6-2, IEC 62040-1, IEC 62477-1, IEC 62619, IEC 62933-5-2, RoHS, UL 9540A, UN 38.3
公开数据表

差异对比

仅显示两家生产商均已公开且数值不同的字段。这不是评判——最佳选择取决于项目需求。

  • 单机柜最大能量: Aqua-C3.0 (S/H Version) — 6.251 MWh; LUNA2000-5015-2S — 5.015 MWh
  • 单机柜最大功率: Aqua-C3.0 (S/H Version) — 3.125 MW; LUNA2000-5015-2S — 2.508 MW
  • 放电时长: Aqua-C3.0 (S/H Version) — 2 h · 4 h; LUNA2000-5015-2S — 2 h
  • 电芯容量: Aqua-C3.0 (S/H Version) — 587 Ah; LUNA2000-5015-2S — 314 Ah
  • 电芯配置: Aqua-C3.0 (S/H Version) — 1P416S×8 (8P416S); LUNA2000-5015-2S — 2P104S per pack (104 cells, 2×314 Ah); container-level configuration not published
  • 模块类型: Aqua-C3.0 (S/H Version) — 交流模块(PCS 集成); LUNA2000-5015-2S — 直流模块
  • PCS 集成: Aqua-C3.0 (S/H Version) — 是; LUNA2000-5015-2S — 否
  • 直流电压: Aqua-C3.0 (S/H Version) — 1123.2–1497.6 V; LUNA2000-5015-2S — 1331.2 rated / 1500 max V
  • Operating temperature: Aqua-C3.0 (S/H Version) — -30…50 (55 optional on H) °C; LUNA2000-5015-2S — -30…55 °C
  • 重量: Aqua-C3.0 (S/H Version) — 47 t; LUNA2000-5015-2S — 43 t
  • 灭火系统: Aqua-C3.0 (S/H Version) — smoke/heat detectors, FACP, ventilation (NFPA 69), dry pipes with sprinklers, aerosol (optional on S), deflagration vent panel (optional); LUNA2000-5015-2S — water sprinkler + NOVEC 1230
  • : Aqua-C3.0 (S/H Version) — 3.0; LUNA2000-5015-2S — 2025
  • 发布: Aqua-C3.0 (S/H Version) — 2025-06; LUNA2000-5015-2S — 2025-05
  • Certifications: Aqua-C3.0 (S/H Version) — CE, CEI 0-16, EN 50549, EN 62477-1, G99, IEC 61000, IEC 62477-1, IEC 62619, IEC 62933, IEC 62993-5-2, IEC 63056, NTS 2.1, NTS SENP 1.1, UL 9540A, UN 38.3/UN 3536, VDE-AR-N 4110, VDE-AR-N 4120; LUNA2000-5015-2S — IEC 61000-6-2, IEC 62040-1, IEC 62477-1, IEC 62619, IEC 62933-5-2, RoHS, UL 9540A, UN 38.3

变体

CLOU Electronics Aqua-C3.0 (S/H Version) 变体

规格型号能量功率时长
Aqua-C3.0H 6250 kWh / 3125 kW @0.5CP (DC, HV box)6.25 MWh3.125 MW2 h
Aqua-C3.0S 6251 kWh / 1563 kVA (string PCS)6.251 MWh1.563 MW4 h

Huawei Digital Power LUNA2000-5015-2S 变体

规格型号能量功率时长
5,015 kWh / 2,507.5 kW (≤ 0.5 CP)5.015 MWh2.508 MW2 h

完整产品卡片

查看 CLOU Electronics Aqua-C3.0 (S/H Version) →查看 Huawei Digital Power LUNA2000-5015-2S →

其他对比

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CLOU Electronics Aqua-C3.0 (S/H Version)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Huawei Digital Power LUNA2000-5015-2SPylontech Container L5000-BAT vs CLOU Electronics Aqua-C3.0 (S/H Version)Pylontech Container L5000-BAT vs Huawei Digital Power LUNA2000-5015-2SSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CLOU Electronics Aqua-C3.0 (S/H Version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs Huawei Digital Power LUNA2000-5015-2SCATL TENER vs CLOU Electronics Aqua-C3.0 (S/H Version)CATL TENER vs Huawei Digital Power LUNA2000-5015-2S