BESS comparison
CLOU Electronics Aqua-C3.0 (S/H Version) vs Huawei Digital Power LUNA2000-5015-2S
Both columns come from what CLOU Electronics and Huawei Digital Power publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.
CLOU Electronics
Aqua-C3.0 (S/H Version)
6.251 MWh
20 ft containerliquid-cooledLFPshipping
Huawei Digital Power
LUNA2000-5015-2S
5.015 MWh
20 ft containerliquid-cooledLFPshipping
Specifications side by side
| Field | CLOU Electronics Aqua-C3.0 (S/H Version) | Huawei Digital Power LUNA2000-5015-2S |
|---|---|---|
| Max energy per enclosure | 6.251 MWh | 5.015 MWh |
| Max power per enclosure | 3.125 MW | 2.508 MW |
| Published durations | 2 h · 4 h | 2 h |
| Segment | utility-scale | utility-scale |
| Status | shipping | shipping |
| Cell chemistry | LFP | LFP |
| Cell capacity | 587 Ah | 314 Ah |
| Cell configuration | 1P416S×8 (8P416S) | 2P104S per pack (104 cells, 2×314 Ah); container-level configuration not published |
| Cell supplier | not published | not published |
| Form factor | 20 ft container | 20 ft container |
| Block type | AC block (PCS integrated) | DC block |
| PCS integrated | yes | no |
| DC voltage | 1123.2–1497.6 V | 1331.2 rated / 1500 max V |
| Cooling | liquid-cooled | liquid-cooled |
| Ingress protection | IP55 | IP55 |
| Operating temperature | -30…50 (55 optional on H) °C | -30…55 °C |
| Dimensions (L × W × H) | 6058 × 2438 × 2896 mm | 6058 × 2438 × 2896 mm |
| Weight | 47 t | 43 t |
| Energy density | not published | not published |
| Round-trip efficiency | not published | not published |
| Cycle life | not published | not published |
| Calendar life | not published | not published |
| Warranty | not published | not published |
| Fire suppression | smoke/heat detectors, FACP, ventilation (NFPA 69), dry pipes with sprinklers, aerosol (optional on S), deflagration vent panel (optional) | water sprinkler + NOVEC 1230 |
| Generation | 3.0 | 2025 |
| Announced | 2025-06 | 2025-05 |
| Certifications | CE, CEI 0-16, EN 50549, EN 62477-1, G99, IEC 61000, IEC 62477-1, IEC 62619, IEC 62933, IEC 62993-5-2, IEC 63056, NTS 2.1, NTS SENP 1.1, UL 9540A, UN 38.3/UN 3536, VDE-AR-N 4110, VDE-AR-N 4120 | IEC 61000-6-2, IEC 62040-1, IEC 62477-1, IEC 62619, IEC 62933-5-2, RoHS, UL 9540A, UN 38.3 |
| Public datasheet | yes | yes |
Where they differ
Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.
- Max energy per enclosure: Aqua-C3.0 (S/H Version) — 6.251 MWh; LUNA2000-5015-2S — 5.015 MWh
- Max power per enclosure: Aqua-C3.0 (S/H Version) — 3.125 MW; LUNA2000-5015-2S — 2.508 MW
- Published durations: Aqua-C3.0 (S/H Version) — 2 h · 4 h; LUNA2000-5015-2S — 2 h
- Cell capacity: Aqua-C3.0 (S/H Version) — 587 Ah; LUNA2000-5015-2S — 314 Ah
- Cell configuration: Aqua-C3.0 (S/H Version) — 1P416S×8 (8P416S); LUNA2000-5015-2S — 2P104S per pack (104 cells, 2×314 Ah); container-level configuration not published
- Block type: Aqua-C3.0 (S/H Version) — AC block (PCS integrated); LUNA2000-5015-2S — DC block
- PCS integrated: Aqua-C3.0 (S/H Version) — yes; LUNA2000-5015-2S — no
- DC voltage: Aqua-C3.0 (S/H Version) — 1123.2–1497.6 V; LUNA2000-5015-2S — 1331.2 rated / 1500 max V
- Operating temperature: Aqua-C3.0 (S/H Version) — -30…50 (55 optional on H) °C; LUNA2000-5015-2S — -30…55 °C
- Weight: Aqua-C3.0 (S/H Version) — 47 t; LUNA2000-5015-2S — 43 t
- Fire suppression: Aqua-C3.0 (S/H Version) — smoke/heat detectors, FACP, ventilation (NFPA 69), dry pipes with sprinklers, aerosol (optional on S), deflagration vent panel (optional); LUNA2000-5015-2S — water sprinkler + NOVEC 1230
- Generation: Aqua-C3.0 (S/H Version) — 3.0; LUNA2000-5015-2S — 2025
- Announced: Aqua-C3.0 (S/H Version) — 2025-06; LUNA2000-5015-2S — 2025-05
- Certifications: Aqua-C3.0 (S/H Version) — CE, CEI 0-16, EN 50549, EN 62477-1, G99, IEC 61000, IEC 62477-1, IEC 62619, IEC 62933, IEC 62993-5-2, IEC 63056, NTS 2.1, NTS SENP 1.1, UL 9540A, UN 38.3/UN 3536, VDE-AR-N 4110, VDE-AR-N 4120; LUNA2000-5015-2S — IEC 61000-6-2, IEC 62040-1, IEC 62477-1, IEC 62619, IEC 62933-5-2, RoHS, UL 9540A, UN 38.3
Variants
CLOU Electronics Aqua-C3.0 (S/H Version) variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| Aqua-C3.0H 6250 kWh / 3125 kW @0.5CP (DC, HV box) | 6.25 MWh | 3.125 MW | 2 h |
| Aqua-C3.0S 6251 kWh / 1563 kVA (string PCS) | 6.251 MWh | 1.563 MW | 4 h |
Huawei Digital Power LUNA2000-5015-2S variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| 5,015 kWh / 2,507.5 kW (≤ 0.5 CP) | 5.015 MWh | 2.508 MW | 2 h |
Full model cards
Open CLOU Electronics Aqua-C3.0 (S/H Version) →Open Huawei Digital Power LUNA2000-5015-2S →
Other comparisons
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CLOU Electronics Aqua-C3.0 (S/H Version)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Huawei Digital Power LUNA2000-5015-2SPylontech Container L5000-BAT vs CLOU Electronics Aqua-C3.0 (S/H Version)Pylontech Container L5000-BAT vs Huawei Digital Power LUNA2000-5015-2SSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CLOU Electronics Aqua-C3.0 (S/H Version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs Huawei Digital Power LUNA2000-5015-2SCATL TENER vs CLOU Electronics Aqua-C3.0 (S/H Version)CATL TENER vs Huawei Digital Power LUNA2000-5015-2S