▮▮Coloprice

储能对比

CLOU Electronics Aqua-C3.0 (S/H Version) vs HyperStrong HyperBlock M (AC version)

两列数据均来自 CLOU Electronics 和 HyperStrong 的公开发布。生产商未公开的字段标记为「未公开」;我们不进行估算或排名。

规格参数对比

字段CLOU Electronics Aqua-C3.0 (S/H Version)HyperStrong HyperBlock M (AC version)
单机柜最大能量6.251 MWh12.8 MWh
单机柜最大功率3.125 MW3.2 MW
放电时长2 h · 4 h4 h
分类公用事业级公用事业级
状态供货中供货中
电芯化学LFPLFP
电芯容量587 Ah601 Ah
电芯配置1P416S×8 (8P416S)8P416S / 16P416S
电芯供应商未公开未公开
形态20 英尺集装箱模块化
模块类型交流模块(PCS 集成)交流模块(PCS 集成)
PCS 集成
直流电压1123.2–1497.6 V1123.2–1497.6 (rated 1331.2) V
散热liquid-cooledliquid-cooled
防护等级IP55Container IP55, Pack IP65, PDU IP55
Operating temperature-30…50 (55 optional on H) °C-30…55 °C
尺寸(长 × 宽 × 高)6058 × 2438 × 2896 mm6058 × 2438 × 2896 mm
重量47 t24 t
能量密度未公开未公开
Round-trip efficiency未公开93%
循环寿命未公开10,000 · >10000cls@SOH70%, 0.5P, to achieve up to 20 years of operation life guarantee
日历寿命未公开20 y
保修期未公开未公开
灭火系统smoke/heat detectors, FACP, ventilation (NFPA 69), dry pipes with sprinklers, aerosol (optional on S), deflagration vent panel (optional)Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection
3.0MagicBlock platform, 2025
发布2025-062025-05
CertificationsCE, CEI 0-16, EN 50549, EN 62477-1, G99, IEC 61000, IEC 62477-1, IEC 62619, IEC 62933, IEC 62993-5-2, IEC 63056, NTS 2.1, NTS SENP 1.1, UL 9540A, UN 38.3/UN 3536, VDE-AR-N 4110, VDE-AR-N 4120EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120
公开数据表

差异对比

仅显示两家生产商均已公开且数值不同的字段。这不是评判——最佳选择取决于项目需求。

  • 单机柜最大能量: Aqua-C3.0 (S/H Version) — 6.251 MWh; HyperBlock M (AC version) — 12.8 MWh
  • 单机柜最大功率: Aqua-C3.0 (S/H Version) — 3.125 MW; HyperBlock M (AC version) — 3.2 MW
  • 放电时长: Aqua-C3.0 (S/H Version) — 2 h · 4 h; HyperBlock M (AC version) — 4 h
  • 电芯容量: Aqua-C3.0 (S/H Version) — 587 Ah; HyperBlock M (AC version) — 601 Ah
  • 电芯配置: Aqua-C3.0 (S/H Version) — 1P416S×8 (8P416S); HyperBlock M (AC version) — 8P416S / 16P416S
  • 形态: Aqua-C3.0 (S/H Version) — 20 英尺集装箱; HyperBlock M (AC version) — 模块化
  • 直流电压: Aqua-C3.0 (S/H Version) — 1123.2–1497.6 V; HyperBlock M (AC version) — 1123.2–1497.6 (rated 1331.2) V
  • 防护等级: Aqua-C3.0 (S/H Version) — IP55; HyperBlock M (AC version) — Container IP55, Pack IP65, PDU IP55
  • Operating temperature: Aqua-C3.0 (S/H Version) — -30…50 (55 optional on H) °C; HyperBlock M (AC version) — -30…55 °C
  • 重量: Aqua-C3.0 (S/H Version) — 47 t; HyperBlock M (AC version) — 24 t
  • 灭火系统: Aqua-C3.0 (S/H Version) — smoke/heat detectors, FACP, ventilation (NFPA 69), dry pipes with sprinklers, aerosol (optional on S), deflagration vent panel (optional); HyperBlock M (AC version) — Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection
  • : Aqua-C3.0 (S/H Version) — 3.0; HyperBlock M (AC version) — MagicBlock platform, 2025
  • 发布: Aqua-C3.0 (S/H Version) — 2025-06; HyperBlock M (AC version) — 2025-05
  • Certifications: Aqua-C3.0 (S/H Version) — CE, CEI 0-16, EN 50549, EN 62477-1, G99, IEC 61000, IEC 62477-1, IEC 62619, IEC 62933, IEC 62993-5-2, IEC 63056, NTS 2.1, NTS SENP 1.1, UL 9540A, UN 38.3/UN 3536, VDE-AR-N 4110, VDE-AR-N 4120; HyperBlock M (AC version) — EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120

仅由其中一家发布:Round-trip efficiency, 循环寿命, 日历寿命。

变体

CLOU Electronics Aqua-C3.0 (S/H Version) 变体

规格型号能量功率时长
Aqua-C3.0H 6250 kWh / 3125 kW @0.5CP (DC, HV box)6.25 MWh3.125 MW2 h
Aqua-C3.0S 6251 kWh / 1563 kVA (string PCS)6.251 MWh1.563 MW4 h

HyperStrong HyperBlock M (AC version) 变体

规格型号能量功率时长
HSL3G71-06400 — 6.4 MWh / 400 kW×46.4 MWh1.6 MW4 h
HSL3G71-12800 — 12.8 MWh / 400 kW×812.8 MWh3.2 MW4 h

完整产品卡片

查看 CLOU Electronics Aqua-C3.0 (S/H Version) →查看 HyperStrong HyperBlock M (AC version) →

其他对比

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CLOU Electronics Aqua-C3.0 (S/H Version)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs HyperStrong HyperBlock M (AC version)Pylontech Container L5000-BAT vs CLOU Electronics Aqua-C3.0 (S/H Version)Pylontech Container L5000-BAT vs HyperStrong HyperBlock M (AC version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CLOU Electronics Aqua-C3.0 (S/H Version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs HyperStrong HyperBlock M (AC version)CATL TENER vs CLOU Electronics Aqua-C3.0 (S/H Version)CATL TENER vs HyperStrong HyperBlock M (AC version)