▮▮Coloprice

BESS comparison

CLOU Electronics Aqua-C3.0 (S/H Version) vs HyperStrong HyperBlock M (AC version)

Both columns come from what CLOU Electronics and HyperStrong publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.

Specifications side by side

FieldCLOU Electronics Aqua-C3.0 (S/H Version)HyperStrong HyperBlock M (AC version)
Max energy per enclosure6.251 MWh12.8 MWh
Max power per enclosure3.125 MW3.2 MW
Published durations2 h · 4 h4 h
Segmentutility-scaleutility-scale
Statusshippingshipping
Cell chemistryLFPLFP
Cell capacity587 Ah601 Ah
Cell configuration1P416S×8 (8P416S)8P416S / 16P416S
Cell suppliernot publishednot published
Form factor20 ft containermodular block
Block typeAC block (PCS integrated)AC block (PCS integrated)
PCS integratedyesyes
DC voltage1123.2–1497.6 V1123.2–1497.6 (rated 1331.2) V
Coolingliquid-cooledliquid-cooled
Ingress protectionIP55Container IP55, Pack IP65, PDU IP55
Operating temperature-30…50 (55 optional on H) °C-30…55 °C
Dimensions (L × W × H)6058 × 2438 × 2896 mm6058 × 2438 × 2896 mm
Weight47 t24 t
Energy densitynot publishednot published
Round-trip efficiencynot published93%
Cycle lifenot published10,000 · >10000cls@SOH70%, 0.5P, to achieve up to 20 years of operation life guarantee
Calendar lifenot published20 y
Warrantynot publishednot published
Fire suppressionsmoke/heat detectors, FACP, ventilation (NFPA 69), dry pipes with sprinklers, aerosol (optional on S), deflagration vent panel (optional)Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection
Generation3.0MagicBlock platform, 2025
Announced2025-062025-05
CertificationsCE, CEI 0-16, EN 50549, EN 62477-1, G99, IEC 61000, IEC 62477-1, IEC 62619, IEC 62933, IEC 62993-5-2, IEC 63056, NTS 2.1, NTS SENP 1.1, UL 9540A, UN 38.3/UN 3536, VDE-AR-N 4110, VDE-AR-N 4120EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120
Public datasheetyesyes

Where they differ

Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.

  • Max energy per enclosure: Aqua-C3.0 (S/H Version) — 6.251 MWh; HyperBlock M (AC version) — 12.8 MWh
  • Max power per enclosure: Aqua-C3.0 (S/H Version) — 3.125 MW; HyperBlock M (AC version) — 3.2 MW
  • Published durations: Aqua-C3.0 (S/H Version) — 2 h · 4 h; HyperBlock M (AC version) — 4 h
  • Cell capacity: Aqua-C3.0 (S/H Version) — 587 Ah; HyperBlock M (AC version) — 601 Ah
  • Cell configuration: Aqua-C3.0 (S/H Version) — 1P416S×8 (8P416S); HyperBlock M (AC version) — 8P416S / 16P416S
  • Form factor: Aqua-C3.0 (S/H Version) — 20 ft container; HyperBlock M (AC version) — modular block
  • DC voltage: Aqua-C3.0 (S/H Version) — 1123.2–1497.6 V; HyperBlock M (AC version) — 1123.2–1497.6 (rated 1331.2) V
  • Ingress protection: Aqua-C3.0 (S/H Version) — IP55; HyperBlock M (AC version) — Container IP55, Pack IP65, PDU IP55
  • Operating temperature: Aqua-C3.0 (S/H Version) — -30…50 (55 optional on H) °C; HyperBlock M (AC version) — -30…55 °C
  • Weight: Aqua-C3.0 (S/H Version) — 47 t; HyperBlock M (AC version) — 24 t
  • Fire suppression: Aqua-C3.0 (S/H Version) — smoke/heat detectors, FACP, ventilation (NFPA 69), dry pipes with sprinklers, aerosol (optional on S), deflagration vent panel (optional); HyperBlock M (AC version) — Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection
  • Generation: Aqua-C3.0 (S/H Version) — 3.0; HyperBlock M (AC version) — MagicBlock platform, 2025
  • Announced: Aqua-C3.0 (S/H Version) — 2025-06; HyperBlock M (AC version) — 2025-05
  • Certifications: Aqua-C3.0 (S/H Version) — CE, CEI 0-16, EN 50549, EN 62477-1, G99, IEC 61000, IEC 62477-1, IEC 62619, IEC 62933, IEC 62993-5-2, IEC 63056, NTS 2.1, NTS SENP 1.1, UL 9540A, UN 38.3/UN 3536, VDE-AR-N 4110, VDE-AR-N 4120; HyperBlock M (AC version) — EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120

Published by only one of the two: Round-trip efficiency, Cycle life, Calendar life.

Variants

CLOU Electronics Aqua-C3.0 (S/H Version) variants

VariantsEnergyPowerDuration
Aqua-C3.0H 6250 kWh / 3125 kW @0.5CP (DC, HV box)6.25 MWh3.125 MW2 h
Aqua-C3.0S 6251 kWh / 1563 kVA (string PCS)6.251 MWh1.563 MW4 h

HyperStrong HyperBlock M (AC version) variants

VariantsEnergyPowerDuration
HSL3G71-06400 — 6.4 MWh / 400 kW×46.4 MWh1.6 MW4 h
HSL3G71-12800 — 12.8 MWh / 400 kW×812.8 MWh3.2 MW4 h

Full model cards

Open CLOU Electronics Aqua-C3.0 (S/H Version) →Open HyperStrong HyperBlock M (AC version) →

Other comparisons

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CLOU Electronics Aqua-C3.0 (S/H Version)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs HyperStrong HyperBlock M (AC version)Pylontech Container L5000-BAT vs CLOU Electronics Aqua-C3.0 (S/H Version)Pylontech Container L5000-BAT vs HyperStrong HyperBlock M (AC version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CLOU Electronics Aqua-C3.0 (S/H Version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs HyperStrong HyperBlock M (AC version)CATL TENER vs CLOU Electronics Aqua-C3.0 (S/H Version)CATL TENER vs HyperStrong HyperBlock M (AC version)