Perbandingan BESS
CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)
Kedua kolom berasal dari informasi yang CRRC Zhuzhou Institute dan REPT BATTERO publikasikan. Bidang yang tidak dipublikasikan oleh salah satu produsen ditandai «tidak dipublikasikan»; kami tidak melakukan estimasi atau peringkat.
CRRC Zhuzhou Institute
6.X Liquid Cooling Energy Storage System
6,901 MWh
kontainer 20 ftberpendingin cairanLFPpengiriman
REPT BATTERO
Powtrix 3.0 DC Container (6.261 MWh)
6,262 MWh
kontainer 20 ftberpendingin cairanLFPpengiriman
Spesifikasi berdampingan
| Bidang | CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System | REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh) |
|---|---|---|
| Energi maks per enklosur | 6,901 MWh | 6,262 MWh |
| Daya maks per enklosur | tidak dipublikasikan | 1,566 MW |
| Durasi yang dipublikasikan | 2 h · 4 h | 4 h |
| Segmen | skala utilitas | skala utilitas |
| Status | pengiriman | pengiriman |
| Kimia sel | LFP | LFP |
| Kapasitas sel | 587 Ah | 392 Ah |
| Konfigurasi sel | 416S4P (10-ft) / 416S8P (20-ft) | 416S12P |
| Pemasok sel | tidak dipublikasikan | tidak dipublikasikan |
| Faktor bentuk | kontainer 20 ft | kontainer 20 ft |
| Jenis blok | blok DC | blok DC |
| PCS terintegrasi | tidak | tidak |
| Tegangan DC | 1081.6–1497.6 V | 1040–1500 V |
| Pendinginan | berpendingin cairan | berpendingin cairan |
| Perlindungan IP | IP55 | IP55 |
| Suhu operasi | -30…55 °C | -30…55 °C |
| Dimensi (P × L × T) | 6058 × 2438 × 2896 mm | 6058 × 2438 × 2896 mm |
| Berat | 48 t | 49 t |
| Kepadatan energi | tidak dipublikasikan | tidak dipublikasikan |
| Efisiensi bolak-balik | tidak dipublikasikan | tidak dipublikasikan |
| Masa pakai siklus | tidak dipublikasikan | tidak dipublikasikan |
| Masa pakai kalender | tidak dipublikasikan | tidak dipublikasikan |
| Garansi | tidak dipublikasikan | tidak dipublikasikan |
| Supresi api | Aerosol-based suppression system; flooded fire protection systems (options); fire alarm panel, heat and smoke detection, alarm bell and strobe | module-level active/passive thermal-runaway protection + container-level fire protection system |
| Generasi | 6.X (2026) | Powtrix 3.0 |
| Diumumkan | 2026-01 | tidak dipublikasikan |
| Sertifikasi | IEC 61000, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL9540A, UN3536, UN38.3 | GB/T 36276-2023, IEC 60730-1-2022, IEC 61000-6-2-2016, IEC 61000-6-4-2018, IEC 62477-1-2012, IEC 62619-2022, IEC 62933-5-2-2022, IEC 63056-2020, IEEE Std 693-2018, ISO 3744-2010, NFPA 68-2023, NFPA 69-2024, NFPA 855, REACH, RoHS, UL 1973-2022, UL 9540-2023, UL 9540A-2019, UN 3536, UN 38.3 |
| Lembar data publik | ya | ya |
Perbedaan
Hanya bidang yang dipublikasikan oleh kedua produsen dan di mana nilainya tidak identik. Bukan penilaian — pilihan yang tepat bergantung pada proyek.
- Energi maks per enklosur: 6.X Liquid Cooling Energy Storage System — 6,901 MWh; Powtrix 3.0 DC Container (6.261 MWh) — 6,262 MWh
- Durasi yang dipublikasikan: 6.X Liquid Cooling Energy Storage System — 2 h · 4 h; Powtrix 3.0 DC Container (6.261 MWh) — 4 h
- Kapasitas sel: 6.X Liquid Cooling Energy Storage System — 587 Ah; Powtrix 3.0 DC Container (6.261 MWh) — 392 Ah
- Konfigurasi sel: 6.X Liquid Cooling Energy Storage System — 416S4P (10-ft) / 416S8P (20-ft); Powtrix 3.0 DC Container (6.261 MWh) — 416S12P
- Tegangan DC: 6.X Liquid Cooling Energy Storage System — 1081.6–1497.6 V; Powtrix 3.0 DC Container (6.261 MWh) — 1040–1500 V
- Berat: 6.X Liquid Cooling Energy Storage System — 48 t; Powtrix 3.0 DC Container (6.261 MWh) — 49 t
- Supresi api: 6.X Liquid Cooling Energy Storage System — Aerosol-based suppression system; flooded fire protection systems (options); fire alarm panel, heat and smoke detection, alarm bell and strobe; Powtrix 3.0 DC Container (6.261 MWh) — module-level active/passive thermal-runaway protection + container-level fire protection system
- Generasi: 6.X Liquid Cooling Energy Storage System — 6.X (2026); Powtrix 3.0 DC Container (6.261 MWh) — Powtrix 3.0
- Sertifikasi: 6.X Liquid Cooling Energy Storage System — IEC 61000, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL9540A, UN3536, UN38.3; Powtrix 3.0 DC Container (6.261 MWh) — GB/T 36276-2023, IEC 60730-1-2022, IEC 61000-6-2-2016, IEC 61000-6-4-2018, IEC 62477-1-2012, IEC 62619-2022, IEC 62933-5-2-2022, IEC 63056-2020, IEEE Std 693-2018, ISO 3744-2010, NFPA 68-2023, NFPA 69-2024, NFPA 855, REACH, RoHS, UL 1973-2022, UL 9540-2023, UL 9540A-2019, UN 3536, UN 38.3
Hanya dipublikasikan oleh salah satu dari keduanya: Daya maks per enklosur, Diumumkan.
Varian
Varian CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System
| Varian | Energi | Daya | Durasi |
|---|---|---|---|
| CESS-L3125-EU-0.5C — 3.125 MWh (10-ft, 587 Ah) | 3,125 MWh | tidak dipublikasikan | 2 h |
| CESS-L3125-EU-0.25C — 3.125 MWh (10-ft, 587 Ah) | 3,125 MWh | tidak dipublikasikan | 4 h |
| CESS-L3450-EU-0.5C — 3.450 MWh (10-ft, 648 Ah) | 3,45 MWh | tidak dipublikasikan | 2 h |
| CESS-L6250-EU-0.5C — 6.250 MWh (20-ft, 587 Ah) | 6,25 MWh | tidak dipublikasikan | 2 h |
| CESS-L6250-EU-0.25C — 6.250 MWh (20-ft, 587 Ah) | 6,25 MWh | tidak dipublikasikan | 4 h |
| CESS-L6901-EU-0.5C — 6.901 MWh (20-ft, 648 Ah) | 6,901 MWh | tidak dipublikasikan | 2 h |
Varian REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)
| Varian | Energi | Daya | Durasi |
|---|---|---|---|
| 6.261 MWh / 1565.5 kW (0.25P) | 6,262 MWh | 1,566 MW | 4 h |
Kartu model lengkap
Buka CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System →Buka REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh) →
Perbandingan lainnya
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)Pylontech Container L5000-BAT vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemPylontech Container L5000-BAT vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)CATL TENER vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemCATL TENER vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)