FieldCRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemREPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)
Max energy per enclosure6.901 MWh6.262 MWh
Max power per enclosurenot published1.566 MW
Published durations2 h · 4 h4 h
Segmentutility-scaleutility-scale
Statusshippingshipping
Cell chemistryLFPLFP
Cell capacity587 Ah392 Ah
Cell configuration416S4P (10-ft) / 416S8P (20-ft)416S12P
Cell suppliernot publishednot published
Form factor20 ft container20 ft container
Block typeDC blockDC block
PCS integratednono
DC voltage1081.6–1497.6 V1040–1500 V
Coolingliquid-cooledliquid-cooled
Ingress protectionIP55IP55
Operating temperature-30…55 °C-30…55 °C
Dimensions (L × W × H)6058 × 2438 × 2896 mm6058 × 2438 × 2896 mm
Weight48 t49 t
Energy densitynot publishednot published
Round-trip efficiencynot publishednot published
Cycle lifenot publishednot published
Calendar lifenot publishednot published
Warrantynot publishednot published
Fire suppressionAerosol-based suppression system; flooded fire protection systems (options); fire alarm panel, heat and smoke detection, alarm bell and strobemodule-level active/passive thermal-runaway protection + container-level fire protection system
Generation6.X (2026)Powtrix 3.0
Announced2026-01not published
CertificationsIEC 61000, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL9540A, UN3536, UN38.3GB/T 36276-2023, IEC 60730-1-2022, IEC 61000-6-2-2016, IEC 61000-6-4-2018, IEC 62477-1-2012, IEC 62619-2022, IEC 62933-5-2-2022, IEC 63056-2020, IEEE Std 693-2018, ISO 3744-2010, NFPA 68-2023, NFPA 69-2024, NFPA 855, REACH, RoHS, UL 1973-2022, UL 9540-2023, UL 9540A-2019, UN 3536, UN 38.3
Public datasheetyesyes

Where they differ

Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.

  • Max energy per enclosure: 6.X Liquid Cooling Energy Storage System — 6.901 MWh; Powtrix 3.0 DC Container (6.261 MWh) — 6.262 MWh
  • Published durations: 6.X Liquid Cooling Energy Storage System — 2 h · 4 h; Powtrix 3.0 DC Container (6.261 MWh) — 4 h
  • Cell capacity: 6.X Liquid Cooling Energy Storage System — 587 Ah; Powtrix 3.0 DC Container (6.261 MWh) — 392 Ah
  • Cell configuration: 6.X Liquid Cooling Energy Storage System — 416S4P (10-ft) / 416S8P (20-ft); Powtrix 3.0 DC Container (6.261 MWh) — 416S12P
  • DC voltage: 6.X Liquid Cooling Energy Storage System — 1081.6–1497.6 V; Powtrix 3.0 DC Container (6.261 MWh) — 1040–1500 V
  • Weight: 6.X Liquid Cooling Energy Storage System — 48 t; Powtrix 3.0 DC Container (6.261 MWh) — 49 t
  • Fire suppression: 6.X Liquid Cooling Energy Storage System — Aerosol-based suppression system; flooded fire protection systems (options); fire alarm panel, heat and smoke detection, alarm bell and strobe; Powtrix 3.0 DC Container (6.261 MWh) — module-level active/passive thermal-runaway protection + container-level fire protection system
  • Generation: 6.X Liquid Cooling Energy Storage System — 6.X (2026); Powtrix 3.0 DC Container (6.261 MWh) — Powtrix 3.0
  • Certifications: 6.X Liquid Cooling Energy Storage System — IEC 61000, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL9540A, UN3536, UN38.3; Powtrix 3.0 DC Container (6.261 MWh) — GB/T 36276-2023, IEC 60730-1-2022, IEC 61000-6-2-2016, IEC 61000-6-4-2018, IEC 62477-1-2012, IEC 62619-2022, IEC 62933-5-2-2022, IEC 63056-2020, IEEE Std 693-2018, ISO 3744-2010, NFPA 68-2023, NFPA 69-2024, NFPA 855, REACH, RoHS, UL 1973-2022, UL 9540-2023, UL 9540A-2019, UN 3536, UN 38.3

Published by only one of the two: Max power per enclosure, Announced.

Variants

CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System variants

VariantsEnergyPowerDuration
CESS-L3125-EU-0.5C — 3.125 MWh (10-ft, 587 Ah)3.125 MWhnot published2 h
CESS-L3125-EU-0.25C — 3.125 MWh (10-ft, 587 Ah)3.125 MWhnot published4 h
CESS-L3450-EU-0.5C — 3.450 MWh (10-ft, 648 Ah)3.45 MWhnot published2 h
CESS-L6250-EU-0.5C — 6.250 MWh (20-ft, 587 Ah)6.25 MWhnot published2 h
CESS-L6250-EU-0.25C — 6.250 MWh (20-ft, 587 Ah)6.25 MWhnot published4 h
CESS-L6901-EU-0.5C — 6.901 MWh (20-ft, 648 Ah)6.901 MWhnot published2 h

REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh) variants

VariantsEnergyPowerDuration
6.261 MWh / 1565.5 kW (0.25P)6.262 MWh1.566 MW4 h

Full model cards

Open CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System →Open REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh) →

Other comparisons

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)Pylontech Container L5000-BAT vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemPylontech Container L5000-BAT vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)CATL TENER vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemCATL TENER vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)