CRRC Zhuzhou Institute
6.X Liquid Cooling Energy Storage System
6.901 MWh
20 英尺集装箱liquid-cooledLFP供货中
HyperStrong
HyperBlock M (AC version)
12.8 MWh
模块化liquid-cooledLFP供货中
规格参数对比
| 字段 | CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System | HyperStrong HyperBlock M (AC version) |
|---|---|---|
| 单机柜最大能量 | 6.901 MWh | 12.8 MWh |
| 单机柜最大功率 | 未公开 | 3.2 MW |
| 放电时长 | 2 h · 4 h | 4 h |
| 分类 | 公用事业级 | 公用事业级 |
| 状态 | 供货中 | 供货中 |
| 电芯化学 | LFP | LFP |
| 电芯容量 | 587 Ah | 601 Ah |
| 电芯配置 | 416S4P (10-ft) / 416S8P (20-ft) | 8P416S / 16P416S |
| 电芯供应商 | 未公开 | 未公开 |
| 形态 | 20 英尺集装箱 | 模块化 |
| 模块类型 | 直流模块 | 交流模块(PCS 集成) |
| PCS 集成 | 否 | 是 |
| 直流电压 | 1081.6–1497.6 V | 1123.2–1497.6 (rated 1331.2) V |
| 散热 | liquid-cooled | liquid-cooled |
| 防护等级 | IP55 | Container IP55, Pack IP65, PDU IP55 |
| Operating temperature | -30…55 °C | -30…55 °C |
| 尺寸(长 × 宽 × 高) | 6058 × 2438 × 2896 mm | 6058 × 2438 × 2896 mm |
| 重量 | 48 t | 24 t |
| 能量密度 | 未公开 | 未公开 |
| Round-trip efficiency | 未公开 | 93% |
| 循环寿命 | 未公开 | 10,000 · >10000cls@SOH70%, 0.5P, to achieve up to 20 years of operation life guarantee |
| 日历寿命 | 未公开 | 20 y |
| 保修期 | 未公开 | 未公开 |
| 灭火系统 | Aerosol-based suppression system; flooded fire protection systems (options); fire alarm panel, heat and smoke detection, alarm bell and strobe | Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection |
| 代 | 6.X (2026) | MagicBlock platform, 2025 |
| 发布 | 2026-01 | 2025-05 |
| Certifications | IEC 61000, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL9540A, UN3536, UN38.3 | EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120 |
| 公开数据表 | 是 | 是 |
差异对比
仅显示两家生产商均已公开且数值不同的字段。这不是评判——最佳选择取决于项目需求。
- 单机柜最大能量: 6.X Liquid Cooling Energy Storage System — 6.901 MWh; HyperBlock M (AC version) — 12.8 MWh
- 放电时长: 6.X Liquid Cooling Energy Storage System — 2 h · 4 h; HyperBlock M (AC version) — 4 h
- 电芯容量: 6.X Liquid Cooling Energy Storage System — 587 Ah; HyperBlock M (AC version) — 601 Ah
- 电芯配置: 6.X Liquid Cooling Energy Storage System — 416S4P (10-ft) / 416S8P (20-ft); HyperBlock M (AC version) — 8P416S / 16P416S
- 形态: 6.X Liquid Cooling Energy Storage System — 20 英尺集装箱; HyperBlock M (AC version) — 模块化
- 模块类型: 6.X Liquid Cooling Energy Storage System — 直流模块; HyperBlock M (AC version) — 交流模块(PCS 集成)
- PCS 集成: 6.X Liquid Cooling Energy Storage System — 否; HyperBlock M (AC version) — 是
- 直流电压: 6.X Liquid Cooling Energy Storage System — 1081.6–1497.6 V; HyperBlock M (AC version) — 1123.2–1497.6 (rated 1331.2) V
- 防护等级: 6.X Liquid Cooling Energy Storage System — IP55; HyperBlock M (AC version) — Container IP55, Pack IP65, PDU IP55
- 重量: 6.X Liquid Cooling Energy Storage System — 48 t; HyperBlock M (AC version) — 24 t
- 灭火系统: 6.X Liquid Cooling Energy Storage System — Aerosol-based suppression system; flooded fire protection systems (options); fire alarm panel, heat and smoke detection, alarm bell and strobe; HyperBlock M (AC version) — Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection
- 代: 6.X Liquid Cooling Energy Storage System — 6.X (2026); HyperBlock M (AC version) — MagicBlock platform, 2025
- 发布: 6.X Liquid Cooling Energy Storage System — 2026-01; HyperBlock M (AC version) — 2025-05
- Certifications: 6.X Liquid Cooling Energy Storage System — IEC 61000, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL9540A, UN3536, UN38.3; HyperBlock M (AC version) — EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120
仅由其中一家发布:单机柜最大功率, Round-trip efficiency, 循环寿命, 日历寿命。
变体
CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System 变体
| 规格型号 | 能量 | 功率 | 时长 |
|---|---|---|---|
| CESS-L3125-EU-0.5C — 3.125 MWh (10-ft, 587 Ah) | 3.125 MWh | 未公开 | 2 h |
| CESS-L3125-EU-0.25C — 3.125 MWh (10-ft, 587 Ah) | 3.125 MWh | 未公开 | 4 h |
| CESS-L3450-EU-0.5C — 3.450 MWh (10-ft, 648 Ah) | 3.45 MWh | 未公开 | 2 h |
| CESS-L6250-EU-0.5C — 6.250 MWh (20-ft, 587 Ah) | 6.25 MWh | 未公开 | 2 h |
| CESS-L6250-EU-0.25C — 6.250 MWh (20-ft, 587 Ah) | 6.25 MWh | 未公开 | 4 h |
| CESS-L6901-EU-0.5C — 6.901 MWh (20-ft, 648 Ah) | 6.901 MWh | 未公开 | 2 h |
HyperStrong HyperBlock M (AC version) 变体
| 规格型号 | 能量 | 功率 | 时长 |
|---|---|---|---|
| HSL3G71-06400 — 6.4 MWh / 400 kW×4 | 6.4 MWh | 1.6 MW | 4 h |
| HSL3G71-12800 — 12.8 MWh / 400 kW×8 | 12.8 MWh | 3.2 MW | 4 h |
完整产品卡片
查看 CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System →查看 HyperStrong HyperBlock M (AC version) →
其他对比
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs HyperStrong HyperBlock M (AC version)Pylontech Container L5000-BAT vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemPylontech Container L5000-BAT vs HyperStrong HyperBlock M (AC version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs HyperStrong HyperBlock M (AC version)CATL TENER vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemCATL TENER vs HyperStrong HyperBlock M (AC version)