▮▮Coloprice

BESS comparison

CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System vs HyperStrong HyperBlock M (AC version)

Both columns come from what CRRC Zhuzhou Institute and HyperStrong publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.

Specifications side by side

FieldCRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemHyperStrong HyperBlock M (AC version)
Max energy per enclosure6.901 MWh12.8 MWh
Max power per enclosurenot published3.2 MW
Published durations2 h · 4 h4 h
Segmentutility-scaleutility-scale
Statusshippingshipping
Cell chemistryLFPLFP
Cell capacity587 Ah601 Ah
Cell configuration416S4P (10-ft) / 416S8P (20-ft)8P416S / 16P416S
Cell suppliernot publishednot published
Form factor20 ft containermodular block
Block typeDC blockAC block (PCS integrated)
PCS integratednoyes
DC voltage1081.6–1497.6 V1123.2–1497.6 (rated 1331.2) V
Coolingliquid-cooledliquid-cooled
Ingress protectionIP55Container IP55, Pack IP65, PDU IP55
Operating temperature-30…55 °C-30…55 °C
Dimensions (L × W × H)6058 × 2438 × 2896 mm6058 × 2438 × 2896 mm
Weight48 t24 t
Energy densitynot publishednot published
Round-trip efficiencynot published93%
Cycle lifenot published10,000 · >10000cls@SOH70%, 0.5P, to achieve up to 20 years of operation life guarantee
Calendar lifenot published20 y
Warrantynot publishednot published
Fire suppressionAerosol-based suppression system; flooded fire protection systems (options); fire alarm panel, heat and smoke detection, alarm bell and strobeCombustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection
Generation6.X (2026)MagicBlock platform, 2025
Announced2026-012025-05
CertificationsIEC 61000, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL9540A, UN3536, UN38.3EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120
Public datasheetyesyes

Where they differ

Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.

  • Max energy per enclosure: 6.X Liquid Cooling Energy Storage System — 6.901 MWh; HyperBlock M (AC version) — 12.8 MWh
  • Published durations: 6.X Liquid Cooling Energy Storage System — 2 h · 4 h; HyperBlock M (AC version) — 4 h
  • Cell capacity: 6.X Liquid Cooling Energy Storage System — 587 Ah; HyperBlock M (AC version) — 601 Ah
  • Cell configuration: 6.X Liquid Cooling Energy Storage System — 416S4P (10-ft) / 416S8P (20-ft); HyperBlock M (AC version) — 8P416S / 16P416S
  • Form factor: 6.X Liquid Cooling Energy Storage System — 20 ft container; HyperBlock M (AC version) — modular block
  • Block type: 6.X Liquid Cooling Energy Storage System — DC block; HyperBlock M (AC version) — AC block (PCS integrated)
  • PCS integrated: 6.X Liquid Cooling Energy Storage System — no; HyperBlock M (AC version) — yes
  • DC voltage: 6.X Liquid Cooling Energy Storage System — 1081.6–1497.6 V; HyperBlock M (AC version) — 1123.2–1497.6 (rated 1331.2) V
  • Ingress protection: 6.X Liquid Cooling Energy Storage System — IP55; HyperBlock M (AC version) — Container IP55, Pack IP65, PDU IP55
  • Weight: 6.X Liquid Cooling Energy Storage System — 48 t; HyperBlock M (AC version) — 24 t
  • Fire suppression: 6.X Liquid Cooling Energy Storage System — Aerosol-based suppression system; flooded fire protection systems (options); fire alarm panel, heat and smoke detection, alarm bell and strobe; HyperBlock M (AC version) — Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection
  • Generation: 6.X Liquid Cooling Energy Storage System — 6.X (2026); HyperBlock M (AC version) — MagicBlock platform, 2025
  • Announced: 6.X Liquid Cooling Energy Storage System — 2026-01; HyperBlock M (AC version) — 2025-05
  • Certifications: 6.X Liquid Cooling Energy Storage System — IEC 61000, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL9540A, UN3536, UN38.3; HyperBlock M (AC version) — EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120

Published by only one of the two: Max power per enclosure, Round-trip efficiency, Cycle life, Calendar life.

Variants

CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System variants

VariantsEnergyPowerDuration
CESS-L3125-EU-0.5C — 3.125 MWh (10-ft, 587 Ah)3.125 MWhnot published2 h
CESS-L3125-EU-0.25C — 3.125 MWh (10-ft, 587 Ah)3.125 MWhnot published4 h
CESS-L3450-EU-0.5C — 3.450 MWh (10-ft, 648 Ah)3.45 MWhnot published2 h
CESS-L6250-EU-0.5C — 6.250 MWh (20-ft, 587 Ah)6.25 MWhnot published2 h
CESS-L6250-EU-0.25C — 6.250 MWh (20-ft, 587 Ah)6.25 MWhnot published4 h
CESS-L6901-EU-0.5C — 6.901 MWh (20-ft, 648 Ah)6.901 MWhnot published2 h

HyperStrong HyperBlock M (AC version) variants

VariantsEnergyPowerDuration
HSL3G71-06400 — 6.4 MWh / 400 kW×46.4 MWh1.6 MW4 h
HSL3G71-12800 — 12.8 MWh / 400 kW×812.8 MWh3.2 MW4 h

Full model cards

Open CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage System →Open HyperStrong HyperBlock M (AC version) →

Other comparisons

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs HyperStrong HyperBlock M (AC version)Pylontech Container L5000-BAT vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemPylontech Container L5000-BAT vs HyperStrong HyperBlock M (AC version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs HyperStrong HyperBlock M (AC version)CATL TENER vs CRRC Zhuzhou Institute 6.X Liquid Cooling Energy Storage SystemCATL TENER vs HyperStrong HyperBlock M (AC version)