▮▮Coloprice

储能对比

HyperStrong HyperBlock M (AC version) vs LG Energy Solution JF2 AC LINK (2HR / 4HR)

两列数据均来自 HyperStrong 和 LG Energy Solution 的公开发布。生产商未公开的字段标记为「未公开」;我们不进行估算或排名。

规格参数对比

字段HyperStrong HyperBlock M (AC version)LG Energy Solution JF2 AC LINK (2HR / 4HR)
单机柜最大能量12.8 MWh5.11 MWh
单机柜最大功率3.2 MW2.55 MW
放电时长4 h2 h · 4 h
分类公用事业级公用事业级
状态供货中供货中
电芯化学LFPLFP
电芯容量601 Ah未公开
电芯配置8P416S / 16P416S14 packs in series × 6 racks in parallel (2HR)
电芯供应商未公开未公开
形态模块化模块化
模块类型交流模块(PCS 集成)交流模块(PCS 集成)
PCS 集成
直流电压1123.2–1497.6 (rated 1331.2) V未公开
散热liquid-cooledliquid-cooled
防护等级Container IP55, Pack IP65, PDU IP55IP55
Operating temperature-30…55 °C-30…50 °C
尺寸(长 × 宽 × 高)6058 × 2438 × 2896 mm7020 × 2570 × 2900 mm
重量24 t48 t
能量密度未公开未公开
Round-trip efficiency93%未公开
循环寿命10,000 · >10000cls@SOH70%, 0.5P, to achieve up to 20 years of operation life guarantee未公开
日历寿命20 y未公开
保修期未公开未公开
灭火系统Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protectiongas detection and active venting system, fire detection and alarm system
MagicBlock platform, 20252024
发布2025-052024-11
CertificationsEN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120IEEE1547, IFC/CFC, NFPA 69, NFPA 72, NFPA 855, UL1642, UL1741 (SA, SB), UL1973, UL9540, UL9540A and large-scale fire testing, UN 38.3
公开数据表

差异对比

仅显示两家生产商均已公开且数值不同的字段。这不是评判——最佳选择取决于项目需求。

  • 单机柜最大能量: HyperBlock M (AC version) — 12.8 MWh; JF2 AC LINK (2HR / 4HR) — 5.11 MWh
  • 单机柜最大功率: HyperBlock M (AC version) — 3.2 MW; JF2 AC LINK (2HR / 4HR) — 2.55 MW
  • 放电时长: HyperBlock M (AC version) — 4 h; JF2 AC LINK (2HR / 4HR) — 2 h · 4 h
  • 电芯配置: HyperBlock M (AC version) — 8P416S / 16P416S; JF2 AC LINK (2HR / 4HR) — 14 packs in series × 6 racks in parallel (2HR)
  • 防护等级: HyperBlock M (AC version) — Container IP55, Pack IP65, PDU IP55; JF2 AC LINK (2HR / 4HR) — IP55
  • Operating temperature: HyperBlock M (AC version) — -30…55 °C; JF2 AC LINK (2HR / 4HR) — -30…50 °C
  • 尺寸(长 × 宽 × 高): HyperBlock M (AC version) — 6058 × 2438 × 2896 mm; JF2 AC LINK (2HR / 4HR) — 7020 × 2570 × 2900 mm
  • 重量: HyperBlock M (AC version) — 24 t; JF2 AC LINK (2HR / 4HR) — 48 t
  • 灭火系统: HyperBlock M (AC version) — Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection; JF2 AC LINK (2HR / 4HR) — gas detection and active venting system, fire detection and alarm system
  • : HyperBlock M (AC version) — MagicBlock platform, 2025; JF2 AC LINK (2HR / 4HR) — 2024
  • 发布: HyperBlock M (AC version) — 2025-05; JF2 AC LINK (2HR / 4HR) — 2024-11
  • Certifications: HyperBlock M (AC version) — EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120; JF2 AC LINK (2HR / 4HR) — IEEE1547, IFC/CFC, NFPA 69, NFPA 72, NFPA 855, UL1642, UL1741 (SA, SB), UL1973, UL9540, UL9540A and large-scale fire testing, UN 38.3

仅由其中一家发布:电芯容量, 直流电压, Round-trip efficiency, 循环寿命, 日历寿命。

变体

HyperStrong HyperBlock M (AC version) 变体

规格型号能量功率时长
HSL3G71-06400 — 6.4 MWh / 400 kW×46.4 MWh1.6 MW4 h
HSL3G71-12800 — 12.8 MWh / 400 kW×812.8 MWh3.2 MW4 h

LG Energy Solution JF2 AC LINK (2HR / 4HR) 变体

规格型号能量功率时长
JF2 2HR AC LINK — 5.11 MWh / 2.55 MW, 690 Vrms, 0.5 CP5.11 MWh2.55 MW2 h
JF2 4HR AC LINK — 5.11 MWh / 1.32 MW (6 × 220 kVA), 690 Vrms, 0.25 CP5.11 MWh1.32 MW4 h

完整产品卡片

查看 HyperStrong HyperBlock M (AC version) →查看 LG Energy Solution JF2 AC LINK (2HR / 4HR) →

其他对比

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs LG Energy Solution JF2 AC LINK (2HR / 4HR)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs HyperStrong HyperBlock M (AC version)Pylontech Container L5000-BAT vs LG Energy Solution JF2 AC LINK (2HR / 4HR)Pylontech Container L5000-BAT vs HyperStrong HyperBlock M (AC version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs LG Energy Solution JF2 AC LINK (2HR / 4HR)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs HyperStrong HyperBlock M (AC version)CATL TENER vs LG Energy Solution JF2 AC LINK (2HR / 4HR)CATL TENER vs HyperStrong HyperBlock M (AC version)