▮▮Coloprice

Prevalon Energy (Nextpower) · utility-scale

Prevalon Energy (Nextpower) HD5 AC

announced

20 ft containerAC block (PCS integrated)liquid-cooledLFP · 315 Ah

Everything below comes from what Prevalon Energy (Nextpower) publishes about the HD5 AC: the datasheet, the product page and press releases. Where a figure is not published, the field says so — we do not estimate.

Schematic illustration — not a manufacturer photo

Variants

5 MWh

Power: 2.5 MW

Verified 2026-08

Variants

Energy figures are nominal (beginning of life) as published by the manufacturer. One model, several duration options — the same enclosure with different power ratings.

VariantsEnergyPowerDuration
5 MWh 2h — inverter DC 2.5 MW / AC 2.63 MVA5 MWh2.5 MW2 h
5 MWh 4h — inverter DC 1.25 MW / AC 1.435 MVA5 MWh1.25 MW4 h
5 MWh 8h — inverter DC 0.625 MW5 MWh625 kW8 h

Specifications

Cell chemistryLFP
Cell capacity315 Ah
Cell configurationnot published
Cell supplierAESC
Form factor20 ft container
Block typeAC block (PCS integrated)
PCS integratedyes
DC voltagenot published
Coolingliquid-cooled
Ingress protectionNEMA 3S / IP55
Operating temperature-30…50 °C
Dimensions (L × W × H)6058 × 2438 × 2896 mm
Weight45 t
Energy densitynot published
Round-trip efficiency90%
Cycle life8,000 · > 8,000 full cycles to 65% SOH; RTE (full depth cycle, 25 °C): 2 hr = 90.00%, 4 hr = 92.50%
Calendar life20 y
Warrantynot published
Fire suppressionDetection and ventilation system compliant with NFPA 69 (redundant ventilation); fire protection per local code is customer-provided
Generation2026
Announced2026-05

Certifications

UL1973UL9540A ed4UL9540UL1741IEEE1547UN38.3NFPA855NFPA70IEEE 693NFPA 69

Key facts

  • 20-ft AC block: liquid-cooled LFP (315 Ah) + integrated string PCS (500 kW fault-isolation blocks), 690 Vac 3-phase to a Prevalon MV transformer (12–34.5 kV)
  • Self-powered auxiliaries (60 kVA max) — no external 480 V supply; hot-commissioning before grid energisation
  • ≥ 426 MWh per acre installed density (incl. inverter-MVT, auxiliaries and augmentation for an assumed 7,300-cycle life)
  • Noise 75 dBA (2h) / 68 dBA (4h) at 1 m; seismic IEEE 693 Moderate (High optional)
  • Spec sheet states figures are 'design estimates only and are not guaranteed'; DC voltage range and 8h AC rating not given

What Prevalon Energy (Nextpower) does not publish for this model

These fields are empty because no public datasheet or release states them. That is information too: ask for these numbers before you shortlist.

Cell configurationDC voltageEnergy densityWarranty

Similar systems from other manufacturers

Sourcing quote for Prevalon Energy (Nextpower) HD5 AC

Coloprice is published by Dream View, a China-sourcing company. For commercial-scale projects we buy BESS containers factory-direct — verified manufacturer, certification review, pre-shipment inspection, export and freight — for a flat 10% fee.

We reply within one business day. No spam, no reselling your contacts.

Sources: Prevalon — HD5 AC product page · HD5 AC spec sheet (PDF, 2026-06-11) · Prevalon — HD5 AC launch press release (2026-05-26) · Prevalon — AESC supply agreement for HD5 DC / HD5 AC (2026-06)