FieldCLOU Electronics Aqua-C3.0 (S/H Version)REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)
Max energy per enclosure6.251 MWh6.262 MWh
Max power per enclosure3.125 MW1.566 MW
Published durations2 h · 4 h4 h
Segmentutility-scaleutility-scale
Statusshippingshipping
Cell chemistryLFPLFP
Cell capacity587 Ah392 Ah
Cell configuration1P416S×8 (8P416S)416S12P
Cell suppliernot publishednot published
Form factor20 ft container20 ft container
Block typeAC block (PCS integrated)DC block
PCS integratedyesno
DC voltage1123.2–1497.6 V1040–1500 V
Coolingliquid-cooledliquid-cooled
Ingress protectionIP55IP55
Operating temperature-30…50 (55 optional on H) °C-30…55 °C
Dimensions (L × W × H)6058 × 2438 × 2896 mm6058 × 2438 × 2896 mm
Weight47 t49 t
Energy densitynot publishednot published
Round-trip efficiencynot publishednot published
Cycle lifenot publishednot published
Calendar lifenot publishednot published
Warrantynot publishednot published
Fire suppressionsmoke/heat detectors, FACP, ventilation (NFPA 69), dry pipes with sprinklers, aerosol (optional on S), deflagration vent panel (optional)module-level active/passive thermal-runaway protection + container-level fire protection system
Generation3.0Powtrix 3.0
Announced2025-06not published
CertificationsCE, CEI 0-16, EN 50549, EN 62477-1, G99, IEC 61000, IEC 62477-1, IEC 62619, IEC 62933, IEC 62993-5-2, IEC 63056, NTS 2.1, NTS SENP 1.1, UL 9540A, UN 38.3/UN 3536, VDE-AR-N 4110, VDE-AR-N 4120GB/T 36276-2023, IEC 60730-1-2022, IEC 61000-6-2-2016, IEC 61000-6-4-2018, IEC 62477-1-2012, IEC 62619-2022, IEC 62933-5-2-2022, IEC 63056-2020, IEEE Std 693-2018, ISO 3744-2010, NFPA 68-2023, NFPA 69-2024, NFPA 855, REACH, RoHS, UL 1973-2022, UL 9540-2023, UL 9540A-2019, UN 3536, UN 38.3
Public datasheetyesyes

Where they differ

Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.

  • Max energy per enclosure: Aqua-C3.0 (S/H Version) — 6.251 MWh; Powtrix 3.0 DC Container (6.261 MWh) — 6.262 MWh
  • Max power per enclosure: Aqua-C3.0 (S/H Version) — 3.125 MW; Powtrix 3.0 DC Container (6.261 MWh) — 1.566 MW
  • Published durations: Aqua-C3.0 (S/H Version) — 2 h · 4 h; Powtrix 3.0 DC Container (6.261 MWh) — 4 h
  • Cell capacity: Aqua-C3.0 (S/H Version) — 587 Ah; Powtrix 3.0 DC Container (6.261 MWh) — 392 Ah
  • Cell configuration: Aqua-C3.0 (S/H Version) — 1P416S×8 (8P416S); Powtrix 3.0 DC Container (6.261 MWh) — 416S12P
  • Block type: Aqua-C3.0 (S/H Version) — AC block (PCS integrated); Powtrix 3.0 DC Container (6.261 MWh) — DC block
  • PCS integrated: Aqua-C3.0 (S/H Version) — yes; Powtrix 3.0 DC Container (6.261 MWh) — no
  • DC voltage: Aqua-C3.0 (S/H Version) — 1123.2–1497.6 V; Powtrix 3.0 DC Container (6.261 MWh) — 1040–1500 V
  • Operating temperature: Aqua-C3.0 (S/H Version) — -30…50 (55 optional on H) °C; Powtrix 3.0 DC Container (6.261 MWh) — -30…55 °C
  • Weight: Aqua-C3.0 (S/H Version) — 47 t; Powtrix 3.0 DC Container (6.261 MWh) — 49 t
  • Fire suppression: Aqua-C3.0 (S/H Version) — smoke/heat detectors, FACP, ventilation (NFPA 69), dry pipes with sprinklers, aerosol (optional on S), deflagration vent panel (optional); Powtrix 3.0 DC Container (6.261 MWh) — module-level active/passive thermal-runaway protection + container-level fire protection system
  • Generation: Aqua-C3.0 (S/H Version) — 3.0; Powtrix 3.0 DC Container (6.261 MWh) — Powtrix 3.0
  • Certifications: Aqua-C3.0 (S/H Version) — CE, CEI 0-16, EN 50549, EN 62477-1, G99, IEC 61000, IEC 62477-1, IEC 62619, IEC 62933, IEC 62993-5-2, IEC 63056, NTS 2.1, NTS SENP 1.1, UL 9540A, UN 38.3/UN 3536, VDE-AR-N 4110, VDE-AR-N 4120; Powtrix 3.0 DC Container (6.261 MWh) — GB/T 36276-2023, IEC 60730-1-2022, IEC 61000-6-2-2016, IEC 61000-6-4-2018, IEC 62477-1-2012, IEC 62619-2022, IEC 62933-5-2-2022, IEC 63056-2020, IEEE Std 693-2018, ISO 3744-2010, NFPA 68-2023, NFPA 69-2024, NFPA 855, REACH, RoHS, UL 1973-2022, UL 9540-2023, UL 9540A-2019, UN 3536, UN 38.3

Published by only one of the two: Announced.

Variants

CLOU Electronics Aqua-C3.0 (S/H Version) variants

VariantsEnergyPowerDuration
Aqua-C3.0H 6250 kWh / 3125 kW @0.5CP (DC, HV box)6.25 MWh3.125 MW2 h
Aqua-C3.0S 6251 kWh / 1563 kVA (string PCS)6.251 MWh1.563 MW4 h

REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh) variants

VariantsEnergyPowerDuration
6.261 MWh / 1565.5 kW (0.25P)6.262 MWh1.566 MW4 h

Full model cards

Open CLOU Electronics Aqua-C3.0 (S/H Version) →Open REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh) →

Other comparisons

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CLOU Electronics Aqua-C3.0 (S/H Version)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)Pylontech Container L5000-BAT vs CLOU Electronics Aqua-C3.0 (S/H Version)Pylontech Container L5000-BAT vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CLOU Electronics Aqua-C3.0 (S/H Version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)CATL TENER vs CLOU Electronics Aqua-C3.0 (S/H Version)CATL TENER vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)