Both columns come from what CATL and CLOU Electronics publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.

Specifications side by side

FieldCATL TENERCLOU Electronics Aqua-C3.0 (S/H Version)
Max energy per enclosure6.25 MWh6.251 MWh
Max power per enclosure3.126 MW3.125 MW
Published durations2 h2 h · 4 h
Segmentutility-scaleutility-scale
Statusshippingshipping
Cell chemistryLFPLFP
Cell capacity587 Ah587 Ah
Cell configuration1P104S×4×8P (pack 1P104S, 4 packs per rack = 1P416S, 8 racks in parallel)1P416S×8 (8P416S)
Cell suppliernot publishednot published
Form factor20 ft container20 ft container
Block typeDC blockAC block (PCS integrated)
PCS integratednoyes
DC voltage1331.2 rated; 1040–1500 range V1123.2–1497.6 V
Coolingliquid-cooledliquid-cooled
Ingress protectionnot publishedIP55
Operating temperature-30…55 °C-30…50 (55 optional on H) °C
Dimensions (L × W × H)not published6058 × 2438 × 2896 mm
Weight45 t47 t
Energy densitynot publishednot published
Round-trip efficiencynot publishednot published
Cycle life8,000 · Cell-level figure from CATL 2026 brochure: 587 Ah cell ≥8,000 cycles (25 °C, 0.5P/0.5P, 70% SOH). System-level cycle life not published; CATL claims zero capacity/power degradation in first five years.not published
Calendar lifenot publishednot published
Warrantynot publishednot published
Fire suppressionnot publishedsmoke/heat detectors, FACP, ventilation (NFPA 69), dry pipes with sprinklers, aerosol (optional on S), deflagration vent panel (optional)
GenerationTENER (2024); Chinese market designation 天恒 C2-L6253.0
Announced2024-042025-06
CertificationsGB 44240-2024, GB/T 34131-2023, GB/T 36276-2023, GB/T 44026-2024CE, CEI 0-16, EN 50549, EN 62477-1, G99, IEC 61000, IEC 62477-1, IEC 62619, IEC 62933, IEC 62993-5-2, IEC 63056, NTS 2.1, NTS SENP 1.1, UL 9540A, UN 38.3/UN 3536, VDE-AR-N 4110, VDE-AR-N 4120
Public datasheetyesyes

Where they differ

Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.

  • Max energy per enclosure: TENER — 6.25 MWh; Aqua-C3.0 (S/H Version) — 6.251 MWh
  • Max power per enclosure: TENER — 3.126 MW; Aqua-C3.0 (S/H Version) — 3.125 MW
  • Published durations: TENER — 2 h; Aqua-C3.0 (S/H Version) — 2 h · 4 h
  • Cell configuration: TENER — 1P104S×4×8P (pack 1P104S, 4 packs per rack = 1P416S, 8 racks in parallel); Aqua-C3.0 (S/H Version) — 1P416S×8 (8P416S)
  • Block type: TENER — DC block; Aqua-C3.0 (S/H Version) — AC block (PCS integrated)
  • PCS integrated: TENER — no; Aqua-C3.0 (S/H Version) — yes
  • DC voltage: TENER — 1331.2 rated; 1040–1500 range V; Aqua-C3.0 (S/H Version) — 1123.2–1497.6 V
  • Operating temperature: TENER — -30…55 °C; Aqua-C3.0 (S/H Version) — -30…50 (55 optional on H) °C
  • Weight: TENER — 45 t; Aqua-C3.0 (S/H Version) — 47 t
  • Generation: TENER — TENER (2024); Chinese market designation 天恒 C2-L625; Aqua-C3.0 (S/H Version) — 3.0
  • Announced: TENER — 2024-04; Aqua-C3.0 (S/H Version) — 2025-06
  • Certifications: TENER — GB 44240-2024, GB/T 34131-2023, GB/T 36276-2023, GB/T 44026-2024; Aqua-C3.0 (S/H Version) — CE, CEI 0-16, EN 50549, EN 62477-1, G99, IEC 61000, IEC 62477-1, IEC 62619, IEC 62933, IEC 62993-5-2, IEC 63056, NTS 2.1, NTS SENP 1.1, UL 9540A, UN 38.3/UN 3536, VDE-AR-N 4110, VDE-AR-N 4120

Published by only one of the two: Ingress protection, Dimensions (L × W × H), Cycle life, Fire suppression.

Variants

CATL TENER variants

VariantsEnergyPowerDuration
6.25 MWh 0.5P (2 × 1562.82 kW); brochure states 2 h/4 h system compatibility6.25 MWh3.126 MW2 h

CLOU Electronics Aqua-C3.0 (S/H Version) variants

VariantsEnergyPowerDuration
Aqua-C3.0H 6250 kWh / 3125 kW @0.5CP (DC, HV box)6.25 MWh3.125 MW2 h
Aqua-C3.0S 6251 kWh / 1563 kVA (string PCS)6.251 MWh1.563 MW4 h

Full model cards

Open CATL TENER →Open CLOU Electronics Aqua-C3.0 (S/H Version) →

Other comparisons

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CATL TENERGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CLOU Electronics Aqua-C3.0 (S/H Version)Pylontech Container L5000-BAT vs CATL TENERPylontech Container L5000-BAT vs CLOU Electronics Aqua-C3.0 (S/H Version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CATL TENERSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CLOU Electronics Aqua-C3.0 (S/H Version)CATL TENER vs Great Power Max-20HC-5000CATL TENER vs HiTHIUM ∞Power 6.25MWh