BESS comparison
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Huawei Digital Power LUNA2000-5015-2S
Both columns come from what Gotion High-Tech and Huawei Digital Power publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.
Gotion High-Tech
Gotion Grid 5 MWh (ESD1331-05P5015)
5.015 MWh
20 ft containerliquid-cooledLFPshipping
Huawei Digital Power
LUNA2000-5015-2S
5.015 MWh
20 ft containerliquid-cooledLFPshipping
Specifications side by side
| Field | Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) | Huawei Digital Power LUNA2000-5015-2S |
|---|---|---|
| Max energy per enclosure | 5.015 MWh | 5.015 MWh |
| Max power per enclosure | not published | 2.508 MW |
| Published durations | not published | 2 h |
| Segment | utility-scale | utility-scale |
| Status | shipping | shipping |
| Cell chemistry | LFP | LFP |
| Cell capacity | 314 Ah | 314 Ah |
| Cell configuration | 1P104S*4*12 | 2P104S per pack (104 cells, 2×314 Ah); container-level configuration not published |
| Cell supplier | not published | not published |
| Form factor | 20 ft container | 20 ft container |
| Block type | DC block | DC block |
| PCS integrated | no | no |
| DC voltage | 1040–1497.6 V | 1331.2 rated / 1500 max V |
| Cooling | liquid-cooled | liquid-cooled |
| Ingress protection | IP55 | IP55 |
| Operating temperature | -30…50 °C | -30…55 °C |
| Dimensions (L × W × H) | 6058 × 2438 × 2896 mm | 6058 × 2438 × 2896 mm |
| Weight | 43 t | 43 t |
| Energy density | not published | not published |
| Round-trip efficiency | not published | not published |
| Cycle life | 12,000 · '12000 cycles' on gotion.asia product page; brochure lists 314 Ah cell cycle life >12000 at 0.5P@25 °C; system test conditions not published | not published |
| Calendar life | not published | not published |
| Warranty | not published | not published |
| Fire suppression | Explosion proof + smoke extraction + PACK-level submerged fire extinguishing + gas extinguishing system + water sprinkler system | water sprinkler + NOVEC 1230 |
| Generation | Liquid Cooling ESS III | 2025 |
| Announced | 2024-02 | 2025-05 |
| Certifications | not published | IEC 61000-6-2, IEC 62040-1, IEC 62477-1, IEC 62619, IEC 62933-5-2, RoHS, UL 9540A, UN 38.3 |
| Public datasheet | no | yes |
Where they differ
Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.
- Cell configuration: Gotion Grid 5 MWh (ESD1331-05P5015) — 1P104S*4*12; LUNA2000-5015-2S — 2P104S per pack (104 cells, 2×314 Ah); container-level configuration not published
- DC voltage: Gotion Grid 5 MWh (ESD1331-05P5015) — 1040–1497.6 V; LUNA2000-5015-2S — 1331.2 rated / 1500 max V
- Operating temperature: Gotion Grid 5 MWh (ESD1331-05P5015) — -30…50 °C; LUNA2000-5015-2S — -30…55 °C
- Fire suppression: Gotion Grid 5 MWh (ESD1331-05P5015) — Explosion proof + smoke extraction + PACK-level submerged fire extinguishing + gas extinguishing system + water sprinkler system; LUNA2000-5015-2S — water sprinkler + NOVEC 1230
- Generation: Gotion Grid 5 MWh (ESD1331-05P5015) — Liquid Cooling ESS III; LUNA2000-5015-2S — 2025
- Announced: Gotion Grid 5 MWh (ESD1331-05P5015) — 2024-02; LUNA2000-5015-2S — 2025-05
- Public datasheet: Gotion Grid 5 MWh (ESD1331-05P5015) — no; LUNA2000-5015-2S — yes
Published by only one of the two: Max power per enclosure, Published durations, Cycle life, Certifications.
Variants
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| 5015 kWh container | 5.015 MWh | not published | not published |
Huawei Digital Power LUNA2000-5015-2S variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| 5,015 kWh / 2,507.5 kW (≤ 0.5 CP) | 5.015 MWh | 2.508 MW | 2 h |
Full model cards
Open Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) →Open Huawei Digital Power LUNA2000-5015-2S →
Other comparisons
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Pylontech Container L5000-BATGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CATL TENERGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Great Power Max-20HC-5000Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs HiTHIUM ∞Power 6.25MWhGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs ZOE Energy Storage Z BOX-P 6200 2HGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs LG Energy Solution JF2 AC LINK (2HR / 4HR)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CALB 20ft 5MWh High-Voltage Liquid-Cooled Container ESS