BESS comparison
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs HyperStrong HyperBlock M (AC version)
Both columns come from what Gotion High-Tech and HyperStrong publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.
Gotion High-Tech
Gotion Grid 5 MWh (ESD1331-05P5015)
5.015 MWh
20 ft containerliquid-cooledLFPshipping
HyperStrong
HyperBlock M (AC version)
12.8 MWh
modular blockliquid-cooledLFPshipping
Specifications side by side
| Field | Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) | HyperStrong HyperBlock M (AC version) |
|---|---|---|
| Max energy per enclosure | 5.015 MWh | 12.8 MWh |
| Max power per enclosure | not published | 3.2 MW |
| Published durations | not published | 4 h |
| Segment | utility-scale | utility-scale |
| Status | shipping | shipping |
| Cell chemistry | LFP | LFP |
| Cell capacity | 314 Ah | 601 Ah |
| Cell configuration | 1P104S*4*12 | 8P416S / 16P416S |
| Cell supplier | not published | not published |
| Form factor | 20 ft container | modular block |
| Block type | DC block | AC block (PCS integrated) |
| PCS integrated | no | yes |
| DC voltage | 1040–1497.6 V | 1123.2–1497.6 (rated 1331.2) V |
| Cooling | liquid-cooled | liquid-cooled |
| Ingress protection | IP55 | Container IP55, Pack IP65, PDU IP55 |
| Operating temperature | -30…50 °C | -30…55 °C |
| Dimensions (L × W × H) | 6058 × 2438 × 2896 mm | 6058 × 2438 × 2896 mm |
| Weight | 43 t | 24 t |
| Energy density | not published | not published |
| Round-trip efficiency | not published | 93% |
| Cycle life | 12,000 · '12000 cycles' on gotion.asia product page; brochure lists 314 Ah cell cycle life >12000 at 0.5P@25 °C; system test conditions not published | 10,000 · >10000cls@SOH70%, 0.5P, to achieve up to 20 years of operation life guarantee |
| Calendar life | not published | 20 y |
| Warranty | not published | not published |
| Fire suppression | Explosion proof + smoke extraction + PACK-level submerged fire extinguishing + gas extinguishing system + water sprinkler system | Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection |
| Generation | Liquid Cooling ESS III | MagicBlock platform, 2025 |
| Announced | 2024-02 | 2025-05 |
| Certifications | not published | EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120 |
| Public datasheet | no | yes |
Where they differ
Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.
- Max energy per enclosure: Gotion Grid 5 MWh (ESD1331-05P5015) — 5.015 MWh; HyperBlock M (AC version) — 12.8 MWh
- Cell capacity: Gotion Grid 5 MWh (ESD1331-05P5015) — 314 Ah; HyperBlock M (AC version) — 601 Ah
- Cell configuration: Gotion Grid 5 MWh (ESD1331-05P5015) — 1P104S*4*12; HyperBlock M (AC version) — 8P416S / 16P416S
- Form factor: Gotion Grid 5 MWh (ESD1331-05P5015) — 20 ft container; HyperBlock M (AC version) — modular block
- Block type: Gotion Grid 5 MWh (ESD1331-05P5015) — DC block; HyperBlock M (AC version) — AC block (PCS integrated)
- PCS integrated: Gotion Grid 5 MWh (ESD1331-05P5015) — no; HyperBlock M (AC version) — yes
- DC voltage: Gotion Grid 5 MWh (ESD1331-05P5015) — 1040–1497.6 V; HyperBlock M (AC version) — 1123.2–1497.6 (rated 1331.2) V
- Ingress protection: Gotion Grid 5 MWh (ESD1331-05P5015) — IP55; HyperBlock M (AC version) — Container IP55, Pack IP65, PDU IP55
- Operating temperature: Gotion Grid 5 MWh (ESD1331-05P5015) — -30…50 °C; HyperBlock M (AC version) — -30…55 °C
- Weight: Gotion Grid 5 MWh (ESD1331-05P5015) — 43 t; HyperBlock M (AC version) — 24 t
- Cycle life: Gotion Grid 5 MWh (ESD1331-05P5015) — 12,000 · '12000 cycles' on gotion.asia product page; brochure lists 314 Ah cell cycle life >12000 at 0.5P@25 °C; system test conditions not published; HyperBlock M (AC version) — 10,000 · >10000cls@SOH70%, 0.5P, to achieve up to 20 years of operation life guarantee
- Fire suppression: Gotion Grid 5 MWh (ESD1331-05P5015) — Explosion proof + smoke extraction + PACK-level submerged fire extinguishing + gas extinguishing system + water sprinkler system; HyperBlock M (AC version) — Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection
- Generation: Gotion Grid 5 MWh (ESD1331-05P5015) — Liquid Cooling ESS III; HyperBlock M (AC version) — MagicBlock platform, 2025
- Announced: Gotion Grid 5 MWh (ESD1331-05P5015) — 2024-02; HyperBlock M (AC version) — 2025-05
- Public datasheet: Gotion Grid 5 MWh (ESD1331-05P5015) — no; HyperBlock M (AC version) — yes
Published by only one of the two: Max power per enclosure, Published durations, Round-trip efficiency, Calendar life, Certifications.
Variants
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| 5015 kWh container | 5.015 MWh | not published | not published |
HyperStrong HyperBlock M (AC version) variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| HSL3G71-06400 — 6.4 MWh / 400 kW×4 | 6.4 MWh | 1.6 MW | 4 h |
| HSL3G71-12800 — 12.8 MWh / 400 kW×8 | 12.8 MWh | 3.2 MW | 4 h |
Full model cards
Open Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) →Open HyperStrong HyperBlock M (AC version) →
Other comparisons
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Pylontech Container L5000-BATGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CATL TENERGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Great Power Max-20HC-5000Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs HiTHIUM ∞Power 6.25MWhGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs ZOE Energy Storage Z BOX-P 6200 2HGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs LG Energy Solution JF2 AC LINK (2HR / 4HR)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CALB 20ft 5MWh High-Voltage Liquid-Cooled Container ESS