BESS comparison
Great Power Max-20HC-5000 vs Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2)
Both columns come from what Great Power and Sunwoda Energy publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.
Great Power
Max-20HC-5000
5 MWh
20 ft containerliquid-cooledLFPshipping
Sunwoda Energy
NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2)
5.015 MWh
20 ft containerliquid-cooledLFPshipping
Specifications side by side
| Field | Great Power Max-20HC-5000 | Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) |
|---|---|---|
| Max energy per enclosure | 5 MWh | 5.015 MWh |
| Max power per enclosure | 2.5 MW | 2.508 MW |
| Published durations | 2 h | 2 h |
| Segment | utility-scale | utility-scale |
| Status | shipping | shipping |
| Cell chemistry | LFP | LFP |
| Cell capacity | 314 Ah | 314 Ah |
| Cell configuration | 1P416S ×12 | 4170 kWh: 1P104S packs (104.49 kWh), 1P416S racks (417 kWh) x10; 5015 kWh: 12P416S |
| Cell supplier | not published | not published |
| Form factor | 20 ft container | 20 ft container |
| Block type | DC block | DC block |
| PCS integrated | no | no |
| DC voltage | 1164.8–1497.8 V | 4170: 1164.8–1497.6 (rated 1331.2); 5015: 1040–1500 (nominal 1331.2) V |
| Cooling | liquid-cooled | liquid-cooled |
| Ingress protection | IP55 | IP55 / NEMA 3R |
| Operating temperature | -35…60 (discharge), -30…50 (charge) °C | 4170: -30…60; 5015: -30…55 °C |
| Dimensions (L × W × H) | 6058 × 2438 × 2896 mm | 6058 × 2438 × 2896 mm |
| Weight | 46 t | 41 t |
| Energy density | not published | not published |
| Round-trip efficiency | 95% | 93% |
| Cycle life | not published | 10,000 · Brochure (2023-11) for 314 Ah cell / NoahX-1500/4170: '10000 cycles @25℃, 0.5CP/0.5CP'. Press release (2023-09) claims cell cycle life 'exceeding 12,000 cycles' and product page for the 314 Ah cell lists 12000 cycles |
| Calendar life | not published | 20 y |
| Warranty | not published | not published |
| Fire suppression | aerosol + water | Water FSS / aerosol (optional); pack-level fire suppression, combustible gas emission and explosion venting (press release) |
| Generation | 2024 | NoahX 2.0, 2023 |
| Announced | 2024-09 | 2023-09 |
| Certifications | GB/T 36276, IEC 61000, IEC 62619, IEC 62933, NFPA 68, NFPA 69, NFPA 72, NFPA 855, UL 1973, UL 9540, UL 9540A | AS3000, GB36276, IEC61000, IEC62477, IEC62619, IEC62933, NFPA68/69, NFPA855, UL1973, UL9540A, UN3536, UN38.3 |
| Public datasheet | yes | yes |
Where they differ
Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.
- Max energy per enclosure: Max-20HC-5000 — 5 MWh; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 5.015 MWh
- Max power per enclosure: Max-20HC-5000 — 2.5 MW; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 2.508 MW
- Cell configuration: Max-20HC-5000 — 1P416S ×12; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 4170 kWh: 1P104S packs (104.49 kWh), 1P416S racks (417 kWh) x10; 5015 kWh: 12P416S
- DC voltage: Max-20HC-5000 — 1164.8–1497.8 V; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 4170: 1164.8–1497.6 (rated 1331.2); 5015: 1040–1500 (nominal 1331.2) V
- Ingress protection: Max-20HC-5000 — IP55; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — IP55 / NEMA 3R
- Operating temperature: Max-20HC-5000 — -35…60 (discharge), -30…50 (charge) °C; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 4170: -30…60; 5015: -30…55 °C
- Weight: Max-20HC-5000 — 46 t; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 41 t
- Round-trip efficiency: Max-20HC-5000 — 95%; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 93%
- Fire suppression: Max-20HC-5000 — aerosol + water; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — Water FSS / aerosol (optional); pack-level fire suppression, combustible gas emission and explosion venting (press release)
- Generation: Max-20HC-5000 — 2024; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — NoahX 2.0, 2023
- Announced: Max-20HC-5000 — 2024-09; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 2023-09
- Certifications: Max-20HC-5000 — GB/T 36276, IEC 61000, IEC 62619, IEC 62933, NFPA 68, NFPA 69, NFPA 72, NFPA 855, UL 1973, UL 9540, UL 9540A; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — AS3000, GB36276, IEC61000, IEC62477, IEC62619, IEC62933, NFPA68/69, NFPA855, UL1973, UL9540A, UN3536, UN38.3
Published by only one of the two: Cycle life, Calendar life.
Variants
Great Power Max-20HC-5000 variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| 5.0 MWh @0.5C (≤417 kW ×6 / 1.25 MW ×2) | 5 MWh | 2.5 MW | 2 h |
Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| NoahX-1500/4170 — 4170 kWh, rated 0.5CP (2085 kW derived from published C-rate) | 4.17 MWh | 2.085 MW | 2 h |
| NoahX-1500/5015-L2 — 5015 kWh, standard 0.5P (2508 kW derived from published C-rate) | 5.015 MWh | 2.508 MW | 2 h |
Full model cards
Open Great Power Max-20HC-5000 →Open Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) →
Other comparisons
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Great Power Max-20HC-5000Pylontech Container L5000-BAT vs Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2)Pylontech Container L5000-BAT vs Great Power Max-20HC-5000Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CATL TENERSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs HiTHIUM ∞Power 6.25MWhSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs ZOE Energy Storage Z BOX-P 6200 2HSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs LG Energy Solution JF2 AC LINK (2HR / 4HR)