BESS comparison
Huawei Digital Power LUNA2000-5015-2S vs LG Energy Solution JF2 AC LINK (2HR / 4HR)
Both columns come from what Huawei Digital Power and LG Energy Solution publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.
Huawei Digital Power
LUNA2000-5015-2S
5.015 MWh
20 ft containerliquid-cooledLFPshipping
LG Energy Solution
JF2 AC LINK (2HR / 4HR)
5.11 MWh
modular blockliquid-cooledLFPshipping
Specifications side by side
| Field | Huawei Digital Power LUNA2000-5015-2S | LG Energy Solution JF2 AC LINK (2HR / 4HR) |
|---|---|---|
| Max energy per enclosure | 5.015 MWh | 5.11 MWh |
| Max power per enclosure | 2.508 MW | 2.55 MW |
| Published durations | 2 h | 2 h · 4 h |
| Segment | utility-scale | utility-scale |
| Status | shipping | shipping |
| Cell chemistry | LFP | LFP |
| Cell capacity | 314 Ah | not published |
| Cell configuration | 2P104S per pack (104 cells, 2×314 Ah); container-level configuration not published | 14 packs in series × 6 racks in parallel (2HR) |
| Cell supplier | not published | not published |
| Form factor | 20 ft container | modular block |
| Block type | DC block | AC block (PCS integrated) |
| PCS integrated | no | yes |
| DC voltage | 1331.2 rated / 1500 max V | not published |
| Cooling | liquid-cooled | liquid-cooled |
| Ingress protection | IP55 | IP55 |
| Operating temperature | -30…55 °C | -30…50 °C |
| Dimensions (L × W × H) | 6058 × 2438 × 2896 mm | 7020 × 2570 × 2900 mm |
| Weight | 43 t | 48 t |
| Energy density | not published | not published |
| Round-trip efficiency | not published | not published |
| Cycle life | not published | not published |
| Calendar life | not published | not published |
| Warranty | not published | not published |
| Fire suppression | water sprinkler + NOVEC 1230 | gas detection and active venting system, fire detection and alarm system |
| Generation | 2025 | 2024 |
| Announced | 2025-05 | 2024-11 |
| Certifications | IEC 61000-6-2, IEC 62040-1, IEC 62477-1, IEC 62619, IEC 62933-5-2, RoHS, UL 9540A, UN 38.3 | IEEE1547, IFC/CFC, NFPA 69, NFPA 72, NFPA 855, UL1642, UL1741 (SA, SB), UL1973, UL9540, UL9540A and large-scale fire testing, UN 38.3 |
| Public datasheet | yes | yes |
Where they differ
Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.
- Max energy per enclosure: LUNA2000-5015-2S — 5.015 MWh; JF2 AC LINK (2HR / 4HR) — 5.11 MWh
- Max power per enclosure: LUNA2000-5015-2S — 2.508 MW; JF2 AC LINK (2HR / 4HR) — 2.55 MW
- Published durations: LUNA2000-5015-2S — 2 h; JF2 AC LINK (2HR / 4HR) — 2 h · 4 h
- Cell configuration: LUNA2000-5015-2S — 2P104S per pack (104 cells, 2×314 Ah); container-level configuration not published; JF2 AC LINK (2HR / 4HR) — 14 packs in series × 6 racks in parallel (2HR)
- Form factor: LUNA2000-5015-2S — 20 ft container; JF2 AC LINK (2HR / 4HR) — modular block
- Block type: LUNA2000-5015-2S — DC block; JF2 AC LINK (2HR / 4HR) — AC block (PCS integrated)
- PCS integrated: LUNA2000-5015-2S — no; JF2 AC LINK (2HR / 4HR) — yes
- Operating temperature: LUNA2000-5015-2S — -30…55 °C; JF2 AC LINK (2HR / 4HR) — -30…50 °C
- Dimensions (L × W × H): LUNA2000-5015-2S — 6058 × 2438 × 2896 mm; JF2 AC LINK (2HR / 4HR) — 7020 × 2570 × 2900 mm
- Weight: LUNA2000-5015-2S — 43 t; JF2 AC LINK (2HR / 4HR) — 48 t
- Fire suppression: LUNA2000-5015-2S — water sprinkler + NOVEC 1230; JF2 AC LINK (2HR / 4HR) — gas detection and active venting system, fire detection and alarm system
- Generation: LUNA2000-5015-2S — 2025; JF2 AC LINK (2HR / 4HR) — 2024
- Announced: LUNA2000-5015-2S — 2025-05; JF2 AC LINK (2HR / 4HR) — 2024-11
- Certifications: LUNA2000-5015-2S — IEC 61000-6-2, IEC 62040-1, IEC 62477-1, IEC 62619, IEC 62933-5-2, RoHS, UL 9540A, UN 38.3; JF2 AC LINK (2HR / 4HR) — IEEE1547, IFC/CFC, NFPA 69, NFPA 72, NFPA 855, UL1642, UL1741 (SA, SB), UL1973, UL9540, UL9540A and large-scale fire testing, UN 38.3
Published by only one of the two: Cell capacity, DC voltage.
Variants
Huawei Digital Power LUNA2000-5015-2S variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| 5,015 kWh / 2,507.5 kW (≤ 0.5 CP) | 5.015 MWh | 2.508 MW | 2 h |
LG Energy Solution JF2 AC LINK (2HR / 4HR) variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| JF2 2HR AC LINK — 5.11 MWh / 2.55 MW, 690 Vrms, 0.5 CP | 5.11 MWh | 2.55 MW | 2 h |
| JF2 4HR AC LINK — 5.11 MWh / 1.32 MW (6 × 220 kVA), 690 Vrms, 0.25 CP | 5.11 MWh | 1.32 MW | 4 h |
Full model cards
Open Huawei Digital Power LUNA2000-5015-2S →Open LG Energy Solution JF2 AC LINK (2HR / 4HR) →
Other comparisons
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs LG Energy Solution JF2 AC LINK (2HR / 4HR)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Huawei Digital Power LUNA2000-5015-2SPylontech Container L5000-BAT vs LG Energy Solution JF2 AC LINK (2HR / 4HR)Pylontech Container L5000-BAT vs Huawei Digital Power LUNA2000-5015-2SSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs LG Energy Solution JF2 AC LINK (2HR / 4HR)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs Huawei Digital Power LUNA2000-5015-2SCATL TENER vs LG Energy Solution JF2 AC LINK (2HR / 4HR)CATL TENER vs Huawei Digital Power LUNA2000-5015-2S