▮▮Coloprice

Equinix NY3

Operational

600 Jefferson Avenue, Secaucus, NJ 07094

Equinix NY3 is a data center in Secaucus, United States, operated by Equinix, currently operational.

Equinix's largest New York metro IBX by disclosed floor space, a 2-story reinforced-concrete building at 600 Jefferson Avenue in Secaucus, New Jersey, with 8 kVA minimum cabinet density and High-Density Cooling available.

Equinix NY3 — schematic illustration
Schematic illustration based on published specifications, not a photograph · air-cooled · in operation
Operator
Equinix
City
Secaucus, United States
Power, MW
Cooling
Air
Floor space
23,305 m²
AI-ready
Yes
ISO 22301ISO 27001ISO 9001PCI DSSSOC 1 Type IISOC 2 Type II
D

Coloprice Score

38 out of 100

Class D · #161 of 574 in United States

  • Resilience10/35
  • Compliance14/20
  • Transparency5/20
  • Scale2/15
  • Maturity7/10
How the score is calculated →
Embed score badge
Equinix NY3 — Coloprice Score 38
<a href="https://coloprice.com/data-centers/usa/secaucus/equinix-ny3-secaucus/?utm_source=score-badge&utm_medium=embed">
  <img src="https://coloprice.com/badge/score/equinix-ny3-secaucus.svg"
    alt="Equinix NY3 — Coloprice Score 38" height="64">
</a>

Connectivity: 1 networks and 1 internet exchanges are present in this facility. Source: PeeringDB →

Equinix NY3 is a 2-story reinforced-concrete building at 600 Jefferson Avenue in Secaucus, New Jersey, the largest facility in the operator's New York metro portfolio by disclosed floor space. It lists 250,853 sq ft (23,305 sqm) of colocation space, more than double the next-largest Secaucus suite. Disclosed specs show N+2 cooling redundancy and N+1 generator redundancy with belly-tank fuel storage; power (UPS) redundancy is not published. Minimum cabinet density is listed at 8 kVA on 240V/415V distribution — the highest density and only higher-voltage suite among the metro cluster besides NY6 and NY11, consistent with a high-density colocation and interconnection role. Floor protection uses double-interlock pre-action suppression with aspirated detection, and the site sits above the 100-year flood elevation. Certifications named are a narrower set than most metro suites: ISO 22301, ISO 27001, ISO 9001, PCI DSS, SOC 1 Type II and SOC 2 Type II — HECVAT, HIPAA, ISO 50001 and NIST are not listed for this facility. Available products include Secure Cabinet Express and High-Density Cooling. Total power capacity in MW, cabinet count and opening year are not published.

  • 250,853 sq ft (23,305 sqm) — largest facility in the NY metro portfolio
  • 8 kVA minimum cabinet density on 240V/415V distribution
  • N+2 cooling, N+1 generator with belly-tank fuel storage; power/UPS redundancy not published
  • Narrower certification set than most metro suites (no HECVAT, HIPAA, ISO 50001, NIST)

Get Quotes

Tell us what you need — we match you with data centers in our catalog and return real quotes. Free for buyers.

We reply within one business day. No spam, no reselling your contacts.

Customer reviews

No reviews yet

Be the first to review — for current or former customers, work email required.

Write a review

Write a review

For current or former customers of this facility. We verify the work email and publish only your role and company — never the email. Text is edited for spelling only.

Your ratings
Uptime & reliability
Support & remote hands
Connectivity & cross-connects
Value for money
Onboarding & contract

Review guidelines →

Operate this facility? Get your free "Listed on Coloprice" badge →

Data release:

More data centers in Secaucus

Source — Verified against operator sources · data pending on-site verification