▮▮Coloprice

CATL · utility-scale

CATL TENER

shipping

20 ft containerDC blockliquid-cooledLFP · 587 AhBNEF Tier 1

Everything below comes from what CATL publishes about the TENER: the datasheet, the product page and press releases. Where a figure is not published, the field says so — we do not estimate.

Schematic illustration — not a manufacturer photo

Variants

6.25 MWh

Power: 3.126 MW

Verified 2026-08

Variants

Energy figures are nominal (beginning of life) as published by the manufacturer. One model, several duration options — the same enclosure with different power ratings.

VariantsEnergyPowerDuration
6.25 MWh 0.5P (2 × 1562.82 kW); brochure states 2 h/4 h system compatibility6.25 MWh3.126 MW2 h

Specifications

Cell chemistryLFP
Cell capacity587 Ah
Cell configuration1P104S×4×8P (pack 1P104S, 4 packs per rack = 1P416S, 8 racks in parallel)
Cell suppliernot published
Form factor20 ft container
Block typeDC block
PCS integratedno
DC voltage1331.2 rated; 1040–1500 range V
Coolingliquid-cooled
Ingress protectionnot published
Operating temperature-30…55 °C
Dimensions (L × W × H)not published
Weight45 t
Energy densitynot published
Round-trip efficiencynot published
Cycle life8,000 · Cell-level figure from CATL 2026 brochure: 587 Ah cell ≥8,000 cycles (25 °C, 0.5P/0.5P, 70% SOH). System-level cycle life not published; CATL claims zero capacity/power degradation in first five years.
Calendar lifenot published
Warrantynot published
Fire suppressionnot published
GenerationTENER (2024); Chinese market designation 天恒 C2-L625
Announced2024-04

Certifications

GB/T 36276-2023GB 44240-2024GB/T 34131-2023GB/T 44026-2024

Key facts

  • 6.25 MWh in a 20-ft container using 587 Ah LFP cells (1878.4 Wh each); 430 Wh/L cell energy density
  • Rated 0.5P charge/discharge power 1562.82 kW × 2 (two DC halves); auxiliary power max 46.5 kW
  • CATL claims zero degradation of capacity and power in the first five years of use
  • Weight ≈45 t, C4 corrosion class, altitude ≤4000 m; communication CAN/RS485, LAN (IEC 61850), dry contacts
  • Deployed at the 602 MWh Solarpro project in Burgas, Bulgaria (grid-connected May 2026)

What CATL does not publish for this model

These fields are empty because no public datasheet or release states them. That is information too: ask for these numbers before you shortlist.

Cell supplierIngress protectionDimensions (L × W × H)Energy densityRound-trip efficiencyCalendar lifeWarrantyFire suppression

Price signal

$75–100/kWh

Our estimate from benchmarks, not a CATL offer: 4-hour LFP systems averaged RMB 541.3/kWh (~$75) in Chinese H1 2026 tenders (CNESA), FOB-China 5MWh DC blocks for Europe ran $71–89/kWh (SMM, June 2026); the market prices a premium over average for TENER's five-year zero-degradation claim. Ex-works China DC block; US/EU turnkey installs run multiples higher ($150–320/kWh installed).

From the Coloprice BESS Price Index — a benchmark, not an offer. See the index for how each figure was collected. See the BESS Price Index →

Similar systems from other manufacturers

Compare

CATL TENER vs Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015)CATL TENER vs Pylontech Container L5000-BATCATL TENER vs Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2)CATL TENER vs Great Power Max-20HC-5000CATL TENER vs HiTHIUM ∞Power 6.25MWhCATL TENER vs ZOE Energy Storage Z BOX-P 6200 2H

Sourcing quote for CATL TENER

Coloprice is published by Dream View, a China-sourcing company. For commercial-scale projects we buy BESS containers factory-direct — verified manufacturer, certification review, pre-shipment inspection, export and freight — for a flat 10% fee.

We reply within one business day. No spam, no reselling your contacts.

Sources: CATL 2026 CN brochure — 天恒C2-L625 6.25MWh 液冷集装箱 spec table (p.17-18) · CATL news — TENER unveiled, 2024-04 · CATL news — TENER at ees Europe 2024 (L-series cells, 430 Wh/L) · CATL news — 602 MWh Bulgaria project with TENER, 2026-05