▮▮Coloprice

BESS comparison

CATL TENER vs Great Power Max-20HC-5000

Both columns come from what CATL and Great Power publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.

Specifications side by side

FieldCATL TENERGreat Power Max-20HC-5000
Max energy per enclosure6.25 MWh5 MWh
Max power per enclosure3.126 MW2.5 MW
Published durations2 h2 h
Segmentutility-scaleutility-scale
Statusshippingshipping
Cell chemistryLFPLFP
Cell capacity587 Ah314 Ah
Cell configuration1P104S×4×8P (pack 1P104S, 4 packs per rack = 1P416S, 8 racks in parallel)1P416S ×12
Cell suppliernot publishednot published
Form factor20 ft container20 ft container
Block typeDC blockDC block
PCS integratednono
DC voltage1331.2 rated; 1040–1500 range V1164.8–1497.8 V
Coolingliquid-cooledliquid-cooled
Ingress protectionnot publishedIP55
Operating temperature-30…55 °C-35…60 (discharge), -30…50 (charge) °C
Dimensions (L × W × H)not published6058 × 2438 × 2896 mm
Weight45 t46 t
Energy densitynot publishednot published
Round-trip efficiencynot published95%
Cycle life8,000 · Cell-level figure from CATL 2026 brochure: 587 Ah cell ≥8,000 cycles (25 °C, 0.5P/0.5P, 70% SOH). System-level cycle life not published; CATL claims zero capacity/power degradation in first five years.not published
Calendar lifenot publishednot published
Warrantynot publishednot published
Fire suppressionnot publishedaerosol + water
GenerationTENER (2024); Chinese market designation 天恒 C2-L6252024
Announced2024-042024-09
CertificationsGB 44240-2024, GB/T 34131-2023, GB/T 36276-2023, GB/T 44026-2024GB/T 36276, IEC 61000, IEC 62619, IEC 62933, NFPA 68, NFPA 69, NFPA 72, NFPA 855, UL 1973, UL 9540, UL 9540A
Public datasheetyesyes

Where they differ

Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.

  • Max energy per enclosure: TENER — 6.25 MWh; Max-20HC-5000 — 5 MWh
  • Max power per enclosure: TENER — 3.126 MW; Max-20HC-5000 — 2.5 MW
  • Cell capacity: TENER — 587 Ah; Max-20HC-5000 — 314 Ah
  • Cell configuration: TENER — 1P104S×4×8P (pack 1P104S, 4 packs per rack = 1P416S, 8 racks in parallel); Max-20HC-5000 — 1P416S ×12
  • DC voltage: TENER — 1331.2 rated; 1040–1500 range V; Max-20HC-5000 — 1164.8–1497.8 V
  • Operating temperature: TENER — -30…55 °C; Max-20HC-5000 — -35…60 (discharge), -30…50 (charge) °C
  • Weight: TENER — 45 t; Max-20HC-5000 — 46 t
  • Generation: TENER — TENER (2024); Chinese market designation 天恒 C2-L625; Max-20HC-5000 — 2024
  • Announced: TENER — 2024-04; Max-20HC-5000 — 2024-09
  • Certifications: TENER — GB 44240-2024, GB/T 34131-2023, GB/T 36276-2023, GB/T 44026-2024; Max-20HC-5000 — GB/T 36276, IEC 61000, IEC 62619, IEC 62933, NFPA 68, NFPA 69, NFPA 72, NFPA 855, UL 1973, UL 9540, UL 9540A

Published by only one of the two: Ingress protection, Dimensions (L × W × H), Round-trip efficiency, Cycle life, Fire suppression.

Variants

CATL TENER variants

VariantsEnergyPowerDuration
6.25 MWh 0.5P (2 × 1562.82 kW); brochure states 2 h/4 h system compatibility6.25 MWh3.126 MW2 h

Great Power Max-20HC-5000 variants

VariantsEnergyPowerDuration
5.0 MWh @0.5C (≤417 kW ×6 / 1.25 MW ×2)5 MWh2.5 MW2 h

Full model cards

Open CATL TENER →Open Great Power Max-20HC-5000 →

Other comparisons

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CATL TENERGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Great Power Max-20HC-5000Pylontech Container L5000-BAT vs CATL TENERPylontech Container L5000-BAT vs Great Power Max-20HC-5000Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CATL TENERSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs Great Power Max-20HC-5000CATL TENER vs HiTHIUM ∞Power 6.25MWhCATL TENER vs ZOE Energy Storage Z BOX-P 6200 2H