BESS comparison
EVE Energy Liquid Cooling BESS Container BP-52-166.4/314-L vs Great Power Max-20HC-5000
Both columns come from what EVE Energy and Great Power publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.
EVE Energy
Liquid Cooling BESS Container BP-52-166.4/314-L
5.016 MWh
20 ft containerliquid-cooledLFPshipping
Great Power
Max-20HC-5000
5 MWh
20 ft containerliquid-cooledLFPshipping
Specifications side by side
| Field | EVE Energy Liquid Cooling BESS Container BP-52-166.4/314-L | Great Power Max-20HC-5000 |
|---|---|---|
| Max energy per enclosure | 5.016 MWh | 5 MWh |
| Max power per enclosure | 2.51 MW | 2.5 MW |
| Published durations | 2 h | 2 h |
| Segment | utility-scale | utility-scale |
| Status | shipping | shipping |
| Cell chemistry | LFP | LFP |
| Cell capacity | 314 Ah | 314 Ah |
| Cell configuration | 12P416S | 1P416S ×12 |
| Cell supplier | not published | not published |
| Form factor | 20 ft container | 20 ft container |
| Block type | DC block | DC block |
| PCS integrated | no | no |
| DC voltage | 1164.8–1497.6 V | 1164.8–1497.8 V |
| Cooling | liquid-cooled | liquid-cooled |
| Ingress protection | IP55 | IP55 |
| Operating temperature | -30…60 °C | -35…60 (discharge), -30…50 (charge) °C |
| Dimensions (L × W × H) | 6200 × 2550 × 2896 mm | 6058 × 2438 × 2896 mm |
| Weight | 43 t | 46 t |
| Energy density | not published | not published |
| Round-trip efficiency | not published | 95% |
| Cycle life | not published | not published |
| Calendar life | not published | not published |
| Warranty | not published | not published |
| Fire suppression | not published | aerosol + water |
| Generation | MB31 (314 Ah) | 2024 |
| Announced | not published | 2024-09 |
| Certifications | UN3536 | GB/T 36276, IEC 61000, IEC 62619, IEC 62933, NFPA 68, NFPA 69, NFPA 72, NFPA 855, UL 1973, UL 9540, UL 9540A |
| Public datasheet | yes | yes |
Where they differ
Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.
- Max energy per enclosure: Liquid Cooling BESS Container BP-52-166.4/314-L — 5.016 MWh; Max-20HC-5000 — 5 MWh
- Max power per enclosure: Liquid Cooling BESS Container BP-52-166.4/314-L — 2.51 MW; Max-20HC-5000 — 2.5 MW
- Cell configuration: Liquid Cooling BESS Container BP-52-166.4/314-L — 12P416S; Max-20HC-5000 — 1P416S ×12
- DC voltage: Liquid Cooling BESS Container BP-52-166.4/314-L — 1164.8–1497.6 V; Max-20HC-5000 — 1164.8–1497.8 V
- Operating temperature: Liquid Cooling BESS Container BP-52-166.4/314-L — -30…60 °C; Max-20HC-5000 — -35…60 (discharge), -30…50 (charge) °C
- Dimensions (L × W × H): Liquid Cooling BESS Container BP-52-166.4/314-L — 6200 × 2550 × 2896 mm; Max-20HC-5000 — 6058 × 2438 × 2896 mm
- Weight: Liquid Cooling BESS Container BP-52-166.4/314-L — 43 t; Max-20HC-5000 — 46 t
- Generation: Liquid Cooling BESS Container BP-52-166.4/314-L — MB31 (314 Ah); Max-20HC-5000 — 2024
- Certifications: Liquid Cooling BESS Container BP-52-166.4/314-L — UN3536; Max-20HC-5000 — GB/T 36276, IEC 61000, IEC 62619, IEC 62933, NFPA 68, NFPA 69, NFPA 72, NFPA 855, UL 1973, UL 9540, UL 9540A
Published by only one of the two: Round-trip efficiency, Fire suppression, Announced.
Variants
EVE Energy Liquid Cooling BESS Container BP-52-166.4/314-L variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| 5016 kWh, 0.5P (2.51 MW per evebatteryusa) | 5.016 MWh | 2.51 MW | 2 h |
Great Power Max-20HC-5000 variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| 5.0 MWh @0.5C (≤417 kW ×6 / 1.25 MW ×2) | 5 MWh | 2.5 MW | 2 h |
Full model cards
Open EVE Energy Liquid Cooling BESS Container BP-52-166.4/314-L →Open Great Power Max-20HC-5000 →
Other comparisons
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Great Power Max-20HC-5000Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs EVE Energy Liquid Cooling BESS Container BP-52-166.4/314-LPylontech Container L5000-BAT vs Great Power Max-20HC-5000Pylontech Container L5000-BAT vs EVE Energy Liquid Cooling BESS Container BP-52-166.4/314-LSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs Great Power Max-20HC-5000Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs EVE Energy Liquid Cooling BESS Container BP-52-166.4/314-LCATL TENER vs Great Power Max-20HC-5000CATL TENER vs EVE Energy Liquid Cooling BESS Container BP-52-166.4/314-L