Equinix SP2 IBX
OperationalEquinix SP2 IBX is a data center in Barueri, Brazil, operated by Equinix, currently operational.
Equinix IBX data center in the Alphaville district of Barueri, part of the operator's São Paulo metro cluster, built with 2N UPS redundancy.

- Operator
- Equinix
- City
- Barueri, Brazil
- Power, MW
- —
- Cooling
- Air
- Floor space
- 3,200 m²
- Market benchmark
- $160 per kW per month wholesale · Brazil
- Index rate for the market, not this operator’s price list
- Address
- Alameda Araguaia, 3641, Alphaville, Barueri · Open in maps ↗
1 sources · data pending on-site verification
Coloprice Score
40 out of 100
Class D · #28 of 245 in Brazil
- Resilience10/35
- Compliance18/20
- Transparency5/20
- Scale0/15
- Maturity7/10
Awards & badges
Earned from the rankings — position in the country, city, category and worldwide lists, plus score axes at their maximum. Free to embed on the operator's site; each badge links back to the list that certifies it.
Equinix SP2 is an IBX data center at Alameda Araguaia 3641 in the Alphaville district of Barueri, part of the São Paulo metro cluster. Equinix lists 3,200 m² (34,444 ft²) of colocation space in a two-storey reinforced-concrete building with 2N UPS redundancy and N+20% cooling redundancy. The generator plant is described in unusual detail: generators are assembled in sets of four units, six power plants in total, with three connected to lines 1 and 2 (N+1) and three on line 3 (N+1), leaving two redundant plants; autonomy is 30 hours or more at full load. Floor load is 250 psf (12 kN/m²) on both raised floor and slab, power distribution is 120 V / 208 V and the minimum cabinet density is 4 kVA. Fire suppression is Novec with aspirated and non-aspirated detection, and the building is above the 500-year base flood elevation. Listed certifications include ISO 9001, 20000-1, 22301, 27001 and 50001, PCI DSS, and SOC 1 and 2 Type II. Total power capacity is not published.
- ▮Colocation space of 3,200 m² (34,444 ft²) in a two-storey reinforced-concrete building.
- ▮2N UPS redundancy and N+20% cooling redundancy.
- ▮Generator plant of six sets of four units; 30+ hours of autonomy at full load.
- ▮Novec fire suppression; building above the 500-year base flood elevation.
- ▮Total power capacity is not published.
Colocation pricing: Brazil & other markets — The Colocation Price Index →
Get Quotes
Tell us what you need — we match you with data centers in our catalog and return real quotes. Free for buyers.
Colocation quotes in Barueri: free, reply within one business day
Get Quotes →Customer reviews
No reviews yet
Be the first to review — for current or former customers, work email required.
Write a review
For current or former customers of this facility. We verify the work email and publish only your role and company — never the email. Text is edited for spelling only.
Operate this facility? Get your free "Listed on Coloprice" badge →
Data release:
More data centers in Barueri
| Facility | Operator | Power, MW | Tier | Status |
|---|---|---|---|---|
| Equinix SP2 IBX | Equinix | — | — | Operational |
| Aligned SP-03 (Barueri) | Aligned Data Centers | 1.6 | III | Operational |
| Scala SGRUTB08 (Tamboré) | Scala Data Centers | 24 | 3 | Operational |
| Scala SGRUTB01 (Tamboré) | Scala Data Centers | 21 | 3 | Operational |
| Scala SGRUTB03 (Tamboré) | Scala Data Centers | 9 | — | Operational |
| Scala SGRUTB04 (Tamboré) | Scala Data Centers | 12 | 3 | Operational |
Source — Verified against operator sources · data pending on-site verification