Ascenty Santiago 2

Operational

Ascenty Santiago 2 is a data center in Santiago, Chile, operated by Ascenty (Digital Realty), with 16 MW of published IT capacity, currently operational.

Ascenty's second Santiago data center, larger than Santiago 1 at 16 MW and 22,000 sqm, with N+2 chiller redundancy.

Ascenty Santiago 2 — schematic illustration
Schematic illustration based on published specifications, not a photograph · air-cooled · in operation
Operator
Ascenty (Digital Realty)
City
Santiago, Chile
Power, MW
16 MW
Cooling
Air
Floor space
22,000 m²
Racks
1,500
ISO 27001PCI-DSSSOC 1 Type IISOC 2 Type IISOC 3 Type II
D

Coloprice Score

43 out of 100

Class D · #4 of 26 in Chile

  • Resilience6/35
  • Compliance9/20
  • Transparency10/20
  • Scale11/15
  • Maturity7/10
How the score is calculated →
Embed score badge
Ascenty Santiago 2 — Coloprice Score 43
<a href="https://coloprice.com/data-centers/chile/santiago/ascenty-santiago-2/?utm_source=score-badge&utm_medium=embed">
  <img src="https://coloprice.com/badge/score/ascenty-santiago-2.svg"
    alt="Ascenty Santiago 2 — Coloprice Score 43" height="64">
</a>

Awards & badges

Earned from the rankings — position in the country, city, category and worldwide lists, plus score axes at their maximum. Free to embed on the operator's site; each badge links back to the list that certifies it.

Ascenty Santiago 2 — Top 10 data centers in Chile 2026
#4 of 26 · See the list →
Ascenty Santiago 2 — Top 3 data centers in Santiago, Chile 2026
#3 of 16 · See the list →

Santiago 2 is the second of Ascenty's three Chilean data centers, substantially larger than the operator's first Santiago building. The site carries a rated power capacity of 16 MW across 22,000 sqm of gross space and approximately 1,500 racks, with a stated UPS capacity of 70,080 kVA. Power distribution uses the same tri-bus design as Ascenty's other Latin American sites — three independent lines per data hall, generator-plus-static-UPS backup in N+1 configuration — while cooling is upgraded to N+2 redundancy on the dual-coil chilled-water plant, one step beyond Santiago 1's N+1 design. The building is rated for Seismic Zone 4 and a maximum floor load of 1,833 kg/m². Ascenty markets the site as carrier-neutral with dedicated telecom meet-me rooms and a direct connection to PIX Chile, and lists ISO 27001, PCI-DSS and SOC 1/2/3 Type II compliance, matching the certification set disclosed for Santiago 1.

  • Second of three Ascenty data centers in Santiago
  • 16 MW site power, 22,000 sqm, ~1,500 racks
  • 70,080 kVA UPS capacity, N+2 chiller redundancy
  • Seismic Zone 4 rated
  • ISO 27001, PCI-DSS, SOC 1/2/3 Type II

Get Quotes

Tell us what you need — we match you with data centers in our catalog and return real quotes. Free for buyers.

We reply within one business day. No spam, no reselling your contacts.

Customer reviews

No reviews yet

Be the first to review — for current or former customers, work email required.

Write a review

Write a review

For current or former customers of this facility. We verify the work email and publish only your role and company — never the email. Text is edited for spelling only.

Your ratings
Uptime & reliability
Support & remote hands
Connectivity & cross-connects
Value for money
Onboarding & contract

Review guidelines →

Operate this facility? Get your free "Listed on Coloprice" badge →

Data release:

More data centers in Santiago

Source — Verified against operator sources · data pending on-site verification