NTT Frankfurt 2 Data Center

Operational

NTT Frankfurt 2 Data Center is a data center in Frankfurt, Germany, operated by NTT Global Data Centers, with 1.1 MW of published IT capacity, currently operational.

Smaller NTT data center on Hanauer Landstraße in Frankfurt, part of the operator's former e-shelter portfolio and enabled for DE-CIX interconnection.

NTT Frankfurt 2 Data Center — schematic illustration
Schematic illustration based on published specifications, not a photograph · air-cooled · in operation

8 of 14 fields published · Operator? Add or correct data →

Units
Operator
NTT Global Data Centers
City
Frankfurt, Germany
Power, MW
1.1 MW
Cooling
Air
Floor space
1,500 m²
Market benchmark
$250 per kW per month wholesale · Frankfurt, Germany
Index rate for the market, not this operator’s price list
Address
Hanauer Landstraße 320, 60314 Frankfurt am Main, Germany · Open in maps ↗

1 sources · data pending on-site verification

E

Coloprice Score

21 out of 100

Class E · #88 of 274 in Germany

  • Resilience0/35
  • Compliance0/20
  • Transparency9/20
  • Scale5/15
  • Maturity7/10
How the score is calculated →
Embed score badge
NTT Frankfurt 2 Data Center — Coloprice Score 21
<a href="https://coloprice.com/data-centers/germany/frankfurt/ntt-frankfurt-2/?utm_source=score-badge&utm_medium=embed">
  <img src="https://coloprice.com/badge/score/ntt-frankfurt-2.svg"
    alt="NTT Frankfurt 2 Data Center — Coloprice Score 21" height="64">
</a>

Connectivity: 15 networks and 1 internet exchanges are present in this facility.

NTT's Frankfurt 2 data center at Hanauer Landstraße 320 in Frankfurt's connectivity-dense eastern district delivers 1.1 MW of critical IT load across roughly 1,500 sqm of server space, fed by an on-site substation rated at 3 MVA and running at an average power density of 1.0 kW per sqm. Cooling is a redundant water-cooled system with N+1 free-cooling support, rather than the air-cooled setups common at NTT's larger campuses. The facility is DE-CIX-enabled and carrier-neutral, with redundant carrier meet-me-rooms and access to major public, private and hybrid cloud providers. Security runs a 24/7 Security Operations Center with 24/7 fallback to NTT's larger Frankfurt 1 facility nearby, plus multilevel security zones and CCTV covering tenant areas. Backup power draws on N+1 UPS systems and generators. NTT describes Frankfurt 2 as one of three smaller sites the company operates in Germany, positioning it below its flagship campuses for customers who need DE-CIX connectivity and Frankfurt-market presence without the scale, or price, of a hyperscale-class facility.

  • ▮1.1 MW critical IT load, roughly 1,500 sqm of server space
  • ▮On-site 3 MVA substation, 1.0 kW/sqm average power density
  • ▮Redundant water-cooled system with N+1 free cooling
  • ▮DE-CIX-enabled, carrier-neutral with redundant Meet-Me-Rooms
  • ▮24/7 Security Operations Center with fallback to NTT Frankfurt 1

Get Quotes

Tell us what you need — we match you with data centers in our catalog and return real quotes. Free for buyers.

We reply within one business day. No spam, no reselling your contacts.

Customer reviews

No reviews yet

Be the first to review — for current or former customers, work email required.

Write a review

Write a review

For current or former customers of this facility. We verify the work email and publish only your role and company — never the email. Text is edited for spelling only.

Your ratings
Uptime & reliability
Support & remote hands
Connectivity & cross-connects
Value for money
Onboarding & contract

Review guidelines →

Operate this facility? Get your free "Listed on Coloprice" badge →

Data release:

Compare with nearby facilities

FacilityOperatorPower, MWTierStatuskm
NTT Frankfurt 2 Data CenterNTT Global Data Centers1.1—Operational0
iNTERWERK RechenzentrumiNTERWERK——Operational<1
maincubes FRA01maincubes6—Operational1
Equinix FR2Equinix——Operational2
INTERNIC FrankfurtINTERNET AG Global Network——Operational5
Equinix FR7Equinix——Operational7

Source — Verified against operator sources · data pending on-site verification