CyrusOne DUR1

Operational

CyrusOne DUR1 is a data center in Durham, NC, United States, operated by CyrusOne, with 50 MW of published IT capacity, currently operational.

CyrusOne data center in Durham, North Carolina delivering 50 MW of IT capacity across 420,000 sq ft in Research Triangle Park.

CyrusOne DUR1 — schematic illustration
Schematic illustration based on published specifications, not a photograph · air-cooled · in operation

8 of 14 fields published · Operator? Add or correct data →

Units
Operator
CyrusOne
City
Durham, NC, United States
Power, MW
50 MW
Cooling
Air
Floor space
39,019 m²
Market benchmark
$196 per kW per month wholesale · United States
Index rate for the market, not this operator’s price list
Address
2223 NE Creek Parkway, Durham, NC 27713 · Open in maps ↗

1 sources · data pending on-site verification

E

Coloprice Score

27 out of 100

Class E · #454 of 1332 in United States

  • Resilience0/35
  • Compliance0/20
  • Transparency9/20
  • Scale11/15
  • Maturity7/10
How the score is calculated →
Embed score badge
CyrusOne DUR1 — Coloprice Score 27
<a href="https://coloprice.com/data-centers/usa/durham/cyrusone-dur1-durham/?utm_source=score-badge&utm_medium=embed">
  <img src="https://coloprice.com/badge/score/cyrusone-dur1-durham.svg"
    alt="CyrusOne DUR1 — Coloprice Score 27" height="64">
</a>

Connectivity: 6 networks and 0 internet exchanges are present in this facility.

CyrusOne's DUR1 sits at 2223 NE Creek Parkway in Durham's Research Triangle Park, close to Raleigh-Durham International Airport, and gives the operator its first purpose-built site in North Carolina. The facility totals 420,000 sq ft of technical IT space, with 92,320 sq ft of raised floor spread across eleven data halls, and delivers 50 MW of IT capacity. Cooling runs on N+2 redundant Trane chillers paired with Liebert 60-ton CRAH units using variable-speed fans. Data halls sit on 42-inch raised white floors under 24-foot ceilings, in a Zone X (low-risk) flood zone and Zone 1-2 seismic rating. Fire protection combines VESDA very-early smoke detection with double-interlocking pre-action sprinklers, and access requires dual authentication into both the building and individual data halls. CyrusOne backs the site with a 100% uptime service level agreement and 24/7 on-site NOCC and remote-hands support, positioning DUR1 as a carrier-neutral option for enterprise and hyperscale tenants expanding into the Raleigh-Durham market.

  • ▮50 MW IT capacity, 420,000 sq ft technical space, 11 data halls
  • ▮N+2 redundant Trane chillers with Liebert CRAH units
  • ▮Zone X flood zone, Zone 1-2 seismic rating
  • ▮100% uptime SLA with 24/7 on-site NOCC
  • ▮First CyrusOne facility in North Carolina, Research Triangle Park

Get Quotes

Tell us what you need — we match you with data centers in our catalog and return real quotes. Free for buyers.

We reply within one business day. No spam, no reselling your contacts.

Customer reviews

No reviews yet

Be the first to review — for current or former customers, work email required.

Write a review

Write a review

For current or former customers of this facility. We verify the work email and publish only your role and company — never the email. Text is edited for spelling only.

Your ratings
Uptime & reliability
Support & remote hands
Connectivity & cross-connects
Value for money
Onboarding & contract

Review guidelines →

Operate this facility? Get your free "Listed on Coloprice" badge →

Data release:

Compare with nearby facilities

FacilityOperatorPower, MWTierStatuskm
CyrusOne DUR1CyrusOne50—Operational0
TierPoint Raleigh-RTPTierPoint——Operational4
Flexential RaleighFlexential4.31—Operational11
TierPoint RaleighTierPoint——Operational27

Source — Verified against operator sources · data pending on-site verification