▮▮Coloprice

BESS comparison

LG Energy Solution JF2 AC LINK (2HR / 4HR) vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)

Both columns come from what LG Energy Solution and REPT BATTERO publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.

Specifications side by side

FieldLG Energy Solution JF2 AC LINK (2HR / 4HR)REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)
Max energy per enclosure5.11 MWh6.262 MWh
Max power per enclosure2.55 MW1.566 MW
Published durations2 h · 4 h4 h
Segmentutility-scaleutility-scale
Statusshippingshipping
Cell chemistryLFPLFP
Cell capacitynot published392 Ah
Cell configuration14 packs in series × 6 racks in parallel (2HR)416S12P
Cell suppliernot publishednot published
Form factormodular block20 ft container
Block typeAC block (PCS integrated)DC block
PCS integratedyesno
DC voltagenot published1040–1500 V
Coolingliquid-cooledliquid-cooled
Ingress protectionIP55IP55
Operating temperature-30…50 °C-30…55 °C
Dimensions (L × W × H)7020 × 2570 × 2900 mm6058 × 2438 × 2896 mm
Weight48 t49 t
Energy densitynot publishednot published
Round-trip efficiencynot publishednot published
Cycle lifenot publishednot published
Calendar lifenot publishednot published
Warrantynot publishednot published
Fire suppressiongas detection and active venting system, fire detection and alarm systemmodule-level active/passive thermal-runaway protection + container-level fire protection system
Generation2024Powtrix 3.0
Announced2024-11not published
CertificationsIEEE1547, IFC/CFC, NFPA 69, NFPA 72, NFPA 855, UL1642, UL1741 (SA, SB), UL1973, UL9540, UL9540A and large-scale fire testing, UN 38.3GB/T 36276-2023, IEC 60730-1-2022, IEC 61000-6-2-2016, IEC 61000-6-4-2018, IEC 62477-1-2012, IEC 62619-2022, IEC 62933-5-2-2022, IEC 63056-2020, IEEE Std 693-2018, ISO 3744-2010, NFPA 68-2023, NFPA 69-2024, NFPA 855, REACH, RoHS, UL 1973-2022, UL 9540-2023, UL 9540A-2019, UN 3536, UN 38.3
Public datasheetyesyes

Where they differ

Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.

  • Max energy per enclosure: JF2 AC LINK (2HR / 4HR) — 5.11 MWh; Powtrix 3.0 DC Container (6.261 MWh) — 6.262 MWh
  • Max power per enclosure: JF2 AC LINK (2HR / 4HR) — 2.55 MW; Powtrix 3.0 DC Container (6.261 MWh) — 1.566 MW
  • Published durations: JF2 AC LINK (2HR / 4HR) — 2 h · 4 h; Powtrix 3.0 DC Container (6.261 MWh) — 4 h
  • Cell configuration: JF2 AC LINK (2HR / 4HR) — 14 packs in series × 6 racks in parallel (2HR); Powtrix 3.0 DC Container (6.261 MWh) — 416S12P
  • Form factor: JF2 AC LINK (2HR / 4HR) — modular block; Powtrix 3.0 DC Container (6.261 MWh) — 20 ft container
  • Block type: JF2 AC LINK (2HR / 4HR) — AC block (PCS integrated); Powtrix 3.0 DC Container (6.261 MWh) — DC block
  • PCS integrated: JF2 AC LINK (2HR / 4HR) — yes; Powtrix 3.0 DC Container (6.261 MWh) — no
  • Operating temperature: JF2 AC LINK (2HR / 4HR) — -30…50 °C; Powtrix 3.0 DC Container (6.261 MWh) — -30…55 °C
  • Dimensions (L × W × H): JF2 AC LINK (2HR / 4HR) — 7020 × 2570 × 2900 mm; Powtrix 3.0 DC Container (6.261 MWh) — 6058 × 2438 × 2896 mm
  • Weight: JF2 AC LINK (2HR / 4HR) — 48 t; Powtrix 3.0 DC Container (6.261 MWh) — 49 t
  • Fire suppression: JF2 AC LINK (2HR / 4HR) — gas detection and active venting system, fire detection and alarm system; Powtrix 3.0 DC Container (6.261 MWh) — module-level active/passive thermal-runaway protection + container-level fire protection system
  • Generation: JF2 AC LINK (2HR / 4HR) — 2024; Powtrix 3.0 DC Container (6.261 MWh) — Powtrix 3.0
  • Certifications: JF2 AC LINK (2HR / 4HR) — IEEE1547, IFC/CFC, NFPA 69, NFPA 72, NFPA 855, UL1642, UL1741 (SA, SB), UL1973, UL9540, UL9540A and large-scale fire testing, UN 38.3; Powtrix 3.0 DC Container (6.261 MWh) — GB/T 36276-2023, IEC 60730-1-2022, IEC 61000-6-2-2016, IEC 61000-6-4-2018, IEC 62477-1-2012, IEC 62619-2022, IEC 62933-5-2-2022, IEC 63056-2020, IEEE Std 693-2018, ISO 3744-2010, NFPA 68-2023, NFPA 69-2024, NFPA 855, REACH, RoHS, UL 1973-2022, UL 9540-2023, UL 9540A-2019, UN 3536, UN 38.3

Published by only one of the two: Cell capacity, DC voltage, Announced.

Variants

LG Energy Solution JF2 AC LINK (2HR / 4HR) variants

VariantsEnergyPowerDuration
JF2 2HR AC LINK — 5.11 MWh / 2.55 MW, 690 Vrms, 0.5 CP5.11 MWh2.55 MW2 h
JF2 4HR AC LINK — 5.11 MWh / 1.32 MW (6 × 220 kVA), 690 Vrms, 0.25 CP5.11 MWh1.32 MW4 h

REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh) variants

VariantsEnergyPowerDuration
6.261 MWh / 1565.5 kW (0.25P)6.262 MWh1.566 MW4 h

Full model cards

Open LG Energy Solution JF2 AC LINK (2HR / 4HR) →Open REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh) →

Other comparisons

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs LG Energy Solution JF2 AC LINK (2HR / 4HR)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)Pylontech Container L5000-BAT vs LG Energy Solution JF2 AC LINK (2HR / 4HR)Pylontech Container L5000-BAT vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs LG Energy Solution JF2 AC LINK (2HR / 4HR)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)CATL TENER vs LG Energy Solution JF2 AC LINK (2HR / 4HR)CATL TENER vs REPT BATTERO Powtrix 3.0 DC Container (6.261 MWh)