Telehouse North Two
OperationalCoriander Avenue, London E14 2AA
Telehouse North Two is a data center in London, United Kingdom, operated by Telehouse, currently operational, opened in 2016.
Telehouse's Docklands data centre opened in 2016 featuring the world's first multi-storey indirect adiabatic cooling system and BREEAM Excellent design.

- Operator
- Telehouse
- City
- London, United Kingdom
- Power, MW
- —
- Cooling
- Air
- Opened
- 2016
Coloprice Score
35 out of 100
Class D · #34 of 109 in United Kingdom
- Resilience6/35
- Compliance15/20
- Transparency4/20
- Scale0/15
- Maturity10/10
Awards & badges
Earned from the rankings — position in the country, city, category and worldwide lists, plus score axes at their maximum. Free to embed on the operator's site; each badge links back to the list that certifies it.
The world's first multi-storey indirect adiabatic cooling system is the engineering claim to fame of Telehouse North Two, which opened in summer 2016 on the operator's Coriander Avenue campus in London Docklands. That cooling design, paired with hot-aisle containment, delivers a published PUE of 1.16 in an N+2 configuration — exceptional for a vertical, inner-city build — and the building is constructed to BREEAM Excellent standard. Power comes from a Telehouse-owned 132kV grid substation on campus, with eight generators totalling 18.5MW at N+1 and average rack provision of 4.5kW plus high-density options. Certifications span ISO 9001, 27001, 14001, 50001 and 22301 along with OHSAS 18001. Its greatest asset is inherited: North Two sits on Europe's most connected campus, with over 530 carriers, ISPs and ASPs on site and around 900 peering ports into LINX. It suits carriers, cloud and content platforms wanting modern efficiency without leaving the Docklands interconnection ecosystem where their traffic already lands.
- ▮Opened summer 2016 with the world's first multi-storey indirect adiabatic cooling
- ▮PUE of 1.16 in N+2 configuration; BREEAM Excellent design
- ▮On-campus 132kV substation; 8 generators totalling 18.5MW
- ▮530+ carriers/ISPs and ~900 LINX peering ports on campus
- ▮ISO 9001/27001/14001/50001/22301 and OHSAS 18001 certified
Colocation pricing: United Kingdom & other markets — The Colocation Price Index →
Get Quotes
Tell us what you need — we match you with data centers in our catalog and return real quotes. Free for buyers.
Customer reviews
No reviews yet
Be the first to review — for current or former customers, work email required.
Write a review
For current or former customers of this facility. We verify the work email and publish only your role and company — never the email. Text is edited for spelling only.
Operate this facility? Get your free "Listed on Coloprice" badge →
Data release:
More data centers in London
Source — Verified against operator sources · data pending on-site verification