▮▮Coloprice

BESS comparison

CATL TENER vs Trina Storage Elementa 2

Both columns come from what CATL and Trina Storage publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.

Specifications side by side

FieldCATL TENERTrina Storage Elementa 2
Max energy per enclosure6.25 MWh5.015 MWh
Max power per enclosure3.126 MWnot published
Published durations2 hnot published
Segmentutility-scaleutility-scale
Statusshippingshipping
Cell chemistryLFPLFP
Cell capacity587 Ah314 Ah
Cell configuration1P104S×4×8P (pack 1P104S, 4 packs per rack = 1P416S, 8 racks in parallel)1P416S12P
Cell suppliernot publishednot published
Form factor20 ft container20 ft container
Block typeDC blockDC block
PCS integratednono
DC voltage1331.2 rated; 1040–1500 range V1123.2–1497.6 V
Coolingliquid-cooledliquid-cooled
Ingress protectionnot publishedIP55 (container, excl. TMS); IP67 module
Operating temperature-30…55 °C-30…50 °C
Dimensions (L × W × H)not published6058 × 2438 × 2896 mm
Weight45 t42.5 t
Energy densitynot publishednot published
Round-trip efficiencynot publishednot published
Cycle life8,000 · Cell-level figure from CATL 2026 brochure: 587 Ah cell ≥8,000 cycles (25 °C, 0.5P/0.5P, 70% SOH). System-level cycle life not published; CATL claims zero capacity/power degradation in first five years.10,000 · Datasheet claim: 'up to 10,000 cycles with 0 degradation in first half year'; test conditions not published
Calendar lifenot publishednot published
Warrantynot publishednot published
Fire suppressionnot publishedautomatic aerosol-based fire suppression system; water-based suppression optional; heat/smoke/gas sensors, active ventilation
GenerationTENER (2024); Chinese market designation 天恒 C2-L6252
Announced2024-04not published
CertificationsGB 44240-2024, GB/T 34131-2023, GB/T 36276-2023, GB/T 44026-2024CE, IEC 61000-6-2/4, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL 1973, UL 9540, UL 9540A, UN38.3
Public datasheetyesyes

Where they differ

Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.

  • Max energy per enclosure: TENER — 6.25 MWh; Elementa 2 — 5.015 MWh
  • Cell capacity: TENER — 587 Ah; Elementa 2 — 314 Ah
  • Cell configuration: TENER — 1P104S×4×8P (pack 1P104S, 4 packs per rack = 1P416S, 8 racks in parallel); Elementa 2 — 1P416S12P
  • DC voltage: TENER — 1331.2 rated; 1040–1500 range V; Elementa 2 — 1123.2–1497.6 V
  • Operating temperature: TENER — -30…55 °C; Elementa 2 — -30…50 °C
  • Weight: TENER — 45 t; Elementa 2 — 42.5 t
  • Cycle life: TENER — 8,000 · Cell-level figure from CATL 2026 brochure: 587 Ah cell ≥8,000 cycles (25 °C, 0.5P/0.5P, 70% SOH). System-level cycle life not published; CATL claims zero capacity/power degradation in first five years.; Elementa 2 — 10,000 · Datasheet claim: 'up to 10,000 cycles with 0 degradation in first half year'; test conditions not published
  • Generation: TENER — TENER (2024); Chinese market designation 天恒 C2-L625; Elementa 2 — 2
  • Certifications: TENER — GB 44240-2024, GB/T 34131-2023, GB/T 36276-2023, GB/T 44026-2024; Elementa 2 — CE, IEC 61000-6-2/4, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL 1973, UL 9540, UL 9540A, UN38.3

Published by only one of the two: Max power per enclosure, Published durations, Ingress protection, Dimensions (L × W × H), Fire suppression, Announced.

Variants

CATL TENER variants

VariantsEnergyPowerDuration
6.25 MWh 0.5P (2 × 1562.82 kW); brochure states 2 h/4 h system compatibility6.25 MWh3.126 MW2 h

Trina Storage Elementa 2 variants

VariantsEnergyPowerDuration
5.015 MWh (314 Ah, 12 racks × 4 modules), 2–4 h5.015 MWhnot publishednot published
4.073 MWh (306 Ah, 1P416S10P, 10 racks × 4 packs), 2–6 h4.073 MWhnot publishednot published

Full model cards

Open CATL TENER →Open Trina Storage Elementa 2 →

Other comparisons

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CATL TENERGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Trina Storage Elementa 2Pylontech Container L5000-BAT vs CATL TENERPylontech Container L5000-BAT vs Trina Storage Elementa 2Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CATL TENERSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs Trina Storage Elementa 2CATL TENER vs Great Power Max-20HC-5000CATL TENER vs HiTHIUM ∞Power 6.25MWh