BESS comparison

CLOU Electronics Aqua-C3.0 (S/H Version) vs Trina Storage Elementa 2

Both columns come from what CLOU Electronics and Trina Storage publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.

Specifications side by side

FieldCLOU Electronics Aqua-C3.0 (S/H Version)Trina Storage Elementa 2
Max energy per enclosure6.251 MWh5.015 MWh
Max power per enclosure3.125 MWnot published
Published durations2 h · 4 hnot published
Segmentutility-scaleutility-scale
Statusshippingshipping
Cell chemistryLFPLFP
Cell capacity587 Ah314 Ah
Cell configuration1P416S×8 (8P416S)1P416S12P
Cell suppliernot publishednot published
Form factor20 ft container20 ft container
Block typeAC block (PCS integrated)DC block
PCS integratedyesno
DC voltage1123.2–1497.6 V1123.2–1497.6 V
Coolingliquid-cooledliquid-cooled
Ingress protectionIP55IP55 (container, excl. TMS); IP67 module
Operating temperature-30…50 (55 optional on H) °C-30…50 °C
Dimensions (L × W × H)6058 × 2438 × 2896 mm6058 × 2438 × 2896 mm
Weight47 t42.5 t
Energy densitynot publishednot published
Round-trip efficiencynot publishednot published
Cycle lifenot published10,000 · Datasheet claim: 'up to 10,000 cycles with 0 degradation in first half year'; test conditions not published
Calendar lifenot publishednot published
Warrantynot publishednot published
Fire suppressionsmoke/heat detectors, FACP, ventilation (NFPA 69), dry pipes with sprinklers, aerosol (optional on S), deflagration vent panel (optional)automatic aerosol-based fire suppression system; water-based suppression optional; heat/smoke/gas sensors, active ventilation
Generation3.02
Announced2025-06not published
CertificationsCE, CEI 0-16, EN 50549, EN 62477-1, G99, IEC 61000, IEC 62477-1, IEC 62619, IEC 62933, IEC 62993-5-2, IEC 63056, NTS 2.1, NTS SENP 1.1, UL 9540A, UN 38.3/UN 3536, VDE-AR-N 4110, VDE-AR-N 4120CE, IEC 61000-6-2/4, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL 1973, UL 9540, UL 9540A, UN38.3
Public datasheetyesyes

Where they differ

Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.

  • Max energy per enclosure: Aqua-C3.0 (S/H Version) — 6.251 MWh; Elementa 2 — 5.015 MWh
  • Cell capacity: Aqua-C3.0 (S/H Version) — 587 Ah; Elementa 2 — 314 Ah
  • Cell configuration: Aqua-C3.0 (S/H Version) — 1P416S×8 (8P416S); Elementa 2 — 1P416S12P
  • Block type: Aqua-C3.0 (S/H Version) — AC block (PCS integrated); Elementa 2 — DC block
  • PCS integrated: Aqua-C3.0 (S/H Version) — yes; Elementa 2 — no
  • Ingress protection: Aqua-C3.0 (S/H Version) — IP55; Elementa 2 — IP55 (container, excl. TMS); IP67 module
  • Operating temperature: Aqua-C3.0 (S/H Version) — -30…50 (55 optional on H) °C; Elementa 2 — -30…50 °C
  • Weight: Aqua-C3.0 (S/H Version) — 47 t; Elementa 2 — 42.5 t
  • Fire suppression: Aqua-C3.0 (S/H Version) — smoke/heat detectors, FACP, ventilation (NFPA 69), dry pipes with sprinklers, aerosol (optional on S), deflagration vent panel (optional); Elementa 2 — automatic aerosol-based fire suppression system; water-based suppression optional; heat/smoke/gas sensors, active ventilation
  • Generation: Aqua-C3.0 (S/H Version) — 3.0; Elementa 2 — 2
  • Certifications: Aqua-C3.0 (S/H Version) — CE, CEI 0-16, EN 50549, EN 62477-1, G99, IEC 61000, IEC 62477-1, IEC 62619, IEC 62933, IEC 62993-5-2, IEC 63056, NTS 2.1, NTS SENP 1.1, UL 9540A, UN 38.3/UN 3536, VDE-AR-N 4110, VDE-AR-N 4120; Elementa 2 — CE, IEC 61000-6-2/4, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL 1973, UL 9540, UL 9540A, UN38.3

Published by only one of the two: Max power per enclosure, Published durations, Cycle life, Announced.

Variants

CLOU Electronics Aqua-C3.0 (S/H Version) variants

VariantsEnergyPowerDuration
Aqua-C3.0H 6250 kWh / 3125 kW @0.5CP (DC, HV box)6.25 MWh3.125 MW2 h
Aqua-C3.0S 6251 kWh / 1563 kVA (string PCS)6.251 MWh1.563 MW4 h

Trina Storage Elementa 2 variants

VariantsEnergyPowerDuration
5.015 MWh (314 Ah, 12 racks × 4 modules), 2–4 h5.015 MWhnot publishednot published
4.073 MWh (306 Ah, 1P416S10P, 10 racks × 4 packs), 2–6 h4.073 MWhnot publishednot published

Full model cards

Open CLOU Electronics Aqua-C3.0 (S/H Version) →Open Trina Storage Elementa 2 →

Other comparisons

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CLOU Electronics Aqua-C3.0 (S/H Version)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Trina Storage Elementa 2Pylontech Container L5000-BAT vs CLOU Electronics Aqua-C3.0 (S/H Version)Pylontech Container L5000-BAT vs Trina Storage Elementa 2Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CLOU Electronics Aqua-C3.0 (S/H Version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs Trina Storage Elementa 2CATL TENER vs CLOU Electronics Aqua-C3.0 (S/H Version)CATL TENER vs Trina Storage Elementa 2