BESS comparison
Huawei Digital Power LUNA2000-5015-2S vs HyperStrong HyperBlock M (AC version)
Both columns come from what Huawei Digital Power and HyperStrong publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.
Huawei Digital Power
LUNA2000-5015-2S
5.015 MWh
20 ft containerliquid-cooledLFPshipping
HyperStrong
HyperBlock M (AC version)
12.8 MWh
modular blockliquid-cooledLFPshipping
Specifications side by side
| Field | Huawei Digital Power LUNA2000-5015-2S | HyperStrong HyperBlock M (AC version) |
|---|---|---|
| Max energy per enclosure | 5.015 MWh | 12.8 MWh |
| Max power per enclosure | 2.508 MW | 3.2 MW |
| Published durations | 2 h | 4 h |
| Segment | utility-scale | utility-scale |
| Status | shipping | shipping |
| Cell chemistry | LFP | LFP |
| Cell capacity | 314 Ah | 601 Ah |
| Cell configuration | 2P104S per pack (104 cells, 2×314 Ah); container-level configuration not published | 8P416S / 16P416S |
| Cell supplier | not published | not published |
| Form factor | 20 ft container | modular block |
| Block type | DC block | AC block (PCS integrated) |
| PCS integrated | no | yes |
| DC voltage | 1331.2 rated / 1500 max V | 1123.2–1497.6 (rated 1331.2) V |
| Cooling | liquid-cooled | liquid-cooled |
| Ingress protection | IP55 | Container IP55, Pack IP65, PDU IP55 |
| Operating temperature | -30…55 °C | -30…55 °C |
| Dimensions (L × W × H) | 6058 × 2438 × 2896 mm | 6058 × 2438 × 2896 mm |
| Weight | 43 t | 24 t |
| Energy density | not published | not published |
| Round-trip efficiency | not published | 93% |
| Cycle life | not published | 10,000 · >10000cls@SOH70%, 0.5P, to achieve up to 20 years of operation life guarantee |
| Calendar life | not published | 20 y |
| Warranty | not published | not published |
| Fire suppression | water sprinkler + NOVEC 1230 | Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection |
| Generation | 2025 | MagicBlock platform, 2025 |
| Announced | 2025-05 | 2025-05 |
| Certifications | IEC 61000-6-2, IEC 62040-1, IEC 62477-1, IEC 62619, IEC 62933-5-2, RoHS, UL 9540A, UN 38.3 | EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120 |
| Public datasheet | yes | yes |
Where they differ
Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.
- Max energy per enclosure: LUNA2000-5015-2S — 5.015 MWh; HyperBlock M (AC version) — 12.8 MWh
- Max power per enclosure: LUNA2000-5015-2S — 2.508 MW; HyperBlock M (AC version) — 3.2 MW
- Published durations: LUNA2000-5015-2S — 2 h; HyperBlock M (AC version) — 4 h
- Cell capacity: LUNA2000-5015-2S — 314 Ah; HyperBlock M (AC version) — 601 Ah
- Cell configuration: LUNA2000-5015-2S — 2P104S per pack (104 cells, 2×314 Ah); container-level configuration not published; HyperBlock M (AC version) — 8P416S / 16P416S
- Form factor: LUNA2000-5015-2S — 20 ft container; HyperBlock M (AC version) — modular block
- Block type: LUNA2000-5015-2S — DC block; HyperBlock M (AC version) — AC block (PCS integrated)
- PCS integrated: LUNA2000-5015-2S — no; HyperBlock M (AC version) — yes
- DC voltage: LUNA2000-5015-2S — 1331.2 rated / 1500 max V; HyperBlock M (AC version) — 1123.2–1497.6 (rated 1331.2) V
- Ingress protection: LUNA2000-5015-2S — IP55; HyperBlock M (AC version) — Container IP55, Pack IP65, PDU IP55
- Weight: LUNA2000-5015-2S — 43 t; HyperBlock M (AC version) — 24 t
- Fire suppression: LUNA2000-5015-2S — water sprinkler + NOVEC 1230; HyperBlock M (AC version) — Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection
- Generation: LUNA2000-5015-2S — 2025; HyperBlock M (AC version) — MagicBlock platform, 2025
- Certifications: LUNA2000-5015-2S — IEC 61000-6-2, IEC 62040-1, IEC 62477-1, IEC 62619, IEC 62933-5-2, RoHS, UL 9540A, UN 38.3; HyperBlock M (AC version) — EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120
Published by only one of the two: Round-trip efficiency, Cycle life, Calendar life.
Variants
Huawei Digital Power LUNA2000-5015-2S variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| 5,015 kWh / 2,507.5 kW (≤ 0.5 CP) | 5.015 MWh | 2.508 MW | 2 h |
HyperStrong HyperBlock M (AC version) variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| HSL3G71-06400 — 6.4 MWh / 400 kW×4 | 6.4 MWh | 1.6 MW | 4 h |
| HSL3G71-12800 — 12.8 MWh / 400 kW×8 | 12.8 MWh | 3.2 MW | 4 h |
Full model cards
Open Huawei Digital Power LUNA2000-5015-2S →Open HyperStrong HyperBlock M (AC version) →
Other comparisons
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Huawei Digital Power LUNA2000-5015-2SGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs HyperStrong HyperBlock M (AC version)Pylontech Container L5000-BAT vs Huawei Digital Power LUNA2000-5015-2SPylontech Container L5000-BAT vs HyperStrong HyperBlock M (AC version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs Huawei Digital Power LUNA2000-5015-2SSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs HyperStrong HyperBlock M (AC version)CATL TENER vs Huawei Digital Power LUNA2000-5015-2SCATL TENER vs HyperStrong HyperBlock M (AC version)