▮▮Coloprice

BESS comparison

CATL TENER vs HyperStrong HyperBlock M (AC version)

Both columns come from what CATL and HyperStrong publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.

Specifications side by side

FieldCATL TENERHyperStrong HyperBlock M (AC version)
Max energy per enclosure6.25 MWh12.8 MWh
Max power per enclosure3.126 MW3.2 MW
Published durations2 h4 h
Segmentutility-scaleutility-scale
Statusshippingshipping
Cell chemistryLFPLFP
Cell capacity587 Ah601 Ah
Cell configuration1P104S×4×8P (pack 1P104S, 4 packs per rack = 1P416S, 8 racks in parallel)8P416S / 16P416S
Cell suppliernot publishednot published
Form factor20 ft containermodular block
Block typeDC blockAC block (PCS integrated)
PCS integratednoyes
DC voltage1331.2 rated; 1040–1500 range V1123.2–1497.6 (rated 1331.2) V
Coolingliquid-cooledliquid-cooled
Ingress protectionnot publishedContainer IP55, Pack IP65, PDU IP55
Operating temperature-30…55 °C-30…55 °C
Dimensions (L × W × H)not published6058 × 2438 × 2896 mm
Weight45 t24 t
Energy densitynot publishednot published
Round-trip efficiencynot published93%
Cycle life8,000 · Cell-level figure from CATL 2026 brochure: 587 Ah cell ≥8,000 cycles (25 °C, 0.5P/0.5P, 70% SOH). System-level cycle life not published; CATL claims zero capacity/power degradation in first five years.10,000 · >10000cls@SOH70%, 0.5P, to achieve up to 20 years of operation life guarantee
Calendar lifenot published20 y
Warrantynot publishednot published
Fire suppressionnot publishedCombustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection
GenerationTENER (2024); Chinese market designation 天恒 C2-L625MagicBlock platform, 2025
Announced2024-042025-05
CertificationsGB 44240-2024, GB/T 34131-2023, GB/T 36276-2023, GB/T 44026-2024EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120
Public datasheetyesyes

Where they differ

Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.

  • Max energy per enclosure: TENER — 6.25 MWh; HyperBlock M (AC version) — 12.8 MWh
  • Max power per enclosure: TENER — 3.126 MW; HyperBlock M (AC version) — 3.2 MW
  • Published durations: TENER — 2 h; HyperBlock M (AC version) — 4 h
  • Cell capacity: TENER — 587 Ah; HyperBlock M (AC version) — 601 Ah
  • Cell configuration: TENER — 1P104S×4×8P (pack 1P104S, 4 packs per rack = 1P416S, 8 racks in parallel); HyperBlock M (AC version) — 8P416S / 16P416S
  • Form factor: TENER — 20 ft container; HyperBlock M (AC version) — modular block
  • Block type: TENER — DC block; HyperBlock M (AC version) — AC block (PCS integrated)
  • PCS integrated: TENER — no; HyperBlock M (AC version) — yes
  • DC voltage: TENER — 1331.2 rated; 1040–1500 range V; HyperBlock M (AC version) — 1123.2–1497.6 (rated 1331.2) V
  • Weight: TENER — 45 t; HyperBlock M (AC version) — 24 t
  • Cycle life: TENER — 8,000 · Cell-level figure from CATL 2026 brochure: 587 Ah cell ≥8,000 cycles (25 °C, 0.5P/0.5P, 70% SOH). System-level cycle life not published; CATL claims zero capacity/power degradation in first five years.; HyperBlock M (AC version) — 10,000 · >10000cls@SOH70%, 0.5P, to achieve up to 20 years of operation life guarantee
  • Generation: TENER — TENER (2024); Chinese market designation 天恒 C2-L625; HyperBlock M (AC version) — MagicBlock platform, 2025
  • Announced: TENER — 2024-04; HyperBlock M (AC version) — 2025-05
  • Certifications: TENER — GB 44240-2024, GB/T 34131-2023, GB/T 36276-2023, GB/T 44026-2024; HyperBlock M (AC version) — EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120

Published by only one of the two: Ingress protection, Dimensions (L × W × H), Round-trip efficiency, Calendar life, Fire suppression.

Variants

CATL TENER variants

VariantsEnergyPowerDuration
6.25 MWh 0.5P (2 × 1562.82 kW); brochure states 2 h/4 h system compatibility6.25 MWh3.126 MW2 h

HyperStrong HyperBlock M (AC version) variants

VariantsEnergyPowerDuration
HSL3G71-06400 — 6.4 MWh / 400 kW×46.4 MWh1.6 MW4 h
HSL3G71-12800 — 12.8 MWh / 400 kW×812.8 MWh3.2 MW4 h

Full model cards

Open CATL TENER →Open HyperStrong HyperBlock M (AC version) →

Other comparisons

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs CATL TENERGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs HyperStrong HyperBlock M (AC version)Pylontech Container L5000-BAT vs CATL TENERPylontech Container L5000-BAT vs HyperStrong HyperBlock M (AC version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CATL TENERSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs HyperStrong HyperBlock M (AC version)CATL TENER vs Great Power Max-20HC-5000CATL TENER vs HiTHIUM ∞Power 6.25MWh