BESS comparison
HyperStrong HyperBlock M (AC version) vs Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2)
Both columns come from what HyperStrong and Sunwoda Energy publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.
HyperStrong
HyperBlock M (AC version)
12.8 MWh
modular blockliquid-cooledLFPshipping
Sunwoda Energy
NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2)
5.015 MWh
20 ft containerliquid-cooledLFPshipping
Specifications side by side
| Field | HyperStrong HyperBlock M (AC version) | Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) |
|---|---|---|
| Max energy per enclosure | 12.8 MWh | 5.015 MWh |
| Max power per enclosure | 3.2 MW | 2.508 MW |
| Published durations | 4 h | 2 h |
| Segment | utility-scale | utility-scale |
| Status | shipping | shipping |
| Cell chemistry | LFP | LFP |
| Cell capacity | 601 Ah | 314 Ah |
| Cell configuration | 8P416S / 16P416S | 4170 kWh: 1P104S packs (104.49 kWh), 1P416S racks (417 kWh) x10; 5015 kWh: 12P416S |
| Cell supplier | not published | not published |
| Form factor | modular block | 20 ft container |
| Block type | AC block (PCS integrated) | DC block |
| PCS integrated | yes | no |
| DC voltage | 1123.2–1497.6 (rated 1331.2) V | 4170: 1164.8–1497.6 (rated 1331.2); 5015: 1040–1500 (nominal 1331.2) V |
| Cooling | liquid-cooled | liquid-cooled |
| Ingress protection | Container IP55, Pack IP65, PDU IP55 | IP55 / NEMA 3R |
| Operating temperature | -30…55 °C | 4170: -30…60; 5015: -30…55 °C |
| Dimensions (L × W × H) | 6058 × 2438 × 2896 mm | 6058 × 2438 × 2896 mm |
| Weight | 24 t | 41 t |
| Energy density | not published | not published |
| Round-trip efficiency | 93% | 93% |
| Cycle life | 10,000 · >10000cls@SOH70%, 0.5P, to achieve up to 20 years of operation life guarantee | 10,000 · Brochure (2023-11) for 314 Ah cell / NoahX-1500/4170: '10000 cycles @25℃, 0.5CP/0.5CP'. Press release (2023-09) claims cell cycle life 'exceeding 12,000 cycles' and product page for the 314 Ah cell lists 12000 cycles |
| Calendar life | 20 y | 20 y |
| Warranty | not published | not published |
| Fire suppression | Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection | Water FSS / aerosol (optional); pack-level fire suppression, combustible gas emission and explosion venting (press release) |
| Generation | MagicBlock platform, 2025 | NoahX 2.0, 2023 |
| Announced | 2025-05 | 2023-09 |
| Certifications | EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120 | AS3000, GB36276, IEC61000, IEC62477, IEC62619, IEC62933, NFPA68/69, NFPA855, UL1973, UL9540A, UN3536, UN38.3 |
| Public datasheet | yes | yes |
Where they differ
Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.
- Max energy per enclosure: HyperBlock M (AC version) — 12.8 MWh; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 5.015 MWh
- Max power per enclosure: HyperBlock M (AC version) — 3.2 MW; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 2.508 MW
- Published durations: HyperBlock M (AC version) — 4 h; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 2 h
- Cell capacity: HyperBlock M (AC version) — 601 Ah; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 314 Ah
- Cell configuration: HyperBlock M (AC version) — 8P416S / 16P416S; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 4170 kWh: 1P104S packs (104.49 kWh), 1P416S racks (417 kWh) x10; 5015 kWh: 12P416S
- Form factor: HyperBlock M (AC version) — modular block; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 20 ft container
- Block type: HyperBlock M (AC version) — AC block (PCS integrated); NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — DC block
- PCS integrated: HyperBlock M (AC version) — yes; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — no
- DC voltage: HyperBlock M (AC version) — 1123.2–1497.6 (rated 1331.2) V; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 4170: 1164.8–1497.6 (rated 1331.2); 5015: 1040–1500 (nominal 1331.2) V
- Ingress protection: HyperBlock M (AC version) — Container IP55, Pack IP65, PDU IP55; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — IP55 / NEMA 3R
- Operating temperature: HyperBlock M (AC version) — -30…55 °C; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 4170: -30…60; 5015: -30…55 °C
- Weight: HyperBlock M (AC version) — 24 t; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 41 t
- Cycle life: HyperBlock M (AC version) — 10,000 · >10000cls@SOH70%, 0.5P, to achieve up to 20 years of operation life guarantee; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 10,000 · Brochure (2023-11) for 314 Ah cell / NoahX-1500/4170: '10000 cycles @25℃, 0.5CP/0.5CP'. Press release (2023-09) claims cell cycle life 'exceeding 12,000 cycles' and product page for the 314 Ah cell lists 12000 cycles
- Fire suppression: HyperBlock M (AC version) — Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — Water FSS / aerosol (optional); pack-level fire suppression, combustible gas emission and explosion venting (press release)
- Generation: HyperBlock M (AC version) — MagicBlock platform, 2025; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — NoahX 2.0, 2023
- Announced: HyperBlock M (AC version) — 2025-05; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — 2023-09
- Certifications: HyperBlock M (AC version) — EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120; NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) — AS3000, GB36276, IEC61000, IEC62477, IEC62619, IEC62933, NFPA68/69, NFPA855, UL1973, UL9540A, UN3536, UN38.3
Variants
HyperStrong HyperBlock M (AC version) variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| HSL3G71-06400 — 6.4 MWh / 400 kW×4 | 6.4 MWh | 1.6 MW | 4 h |
| HSL3G71-12800 — 12.8 MWh / 400 kW×8 | 12.8 MWh | 3.2 MW | 4 h |
Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| NoahX-1500/4170 — 4170 kWh, rated 0.5CP (2085 kW derived from published C-rate) | 4.17 MWh | 2.085 MW | 2 h |
| NoahX-1500/5015-L2 — 5015 kWh, standard 0.5P (2508 kW derived from published C-rate) | 5.015 MWh | 2.508 MW | 2 h |
Full model cards
Open HyperStrong HyperBlock M (AC version) →Open Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) →
Other comparisons
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs HyperStrong HyperBlock M (AC version)Pylontech Container L5000-BAT vs Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2)Pylontech Container L5000-BAT vs HyperStrong HyperBlock M (AC version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs CATL TENERSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs Great Power Max-20HC-5000Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs HiTHIUM ∞Power 6.25MWhSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs ZOE Energy Storage Z BOX-P 6200 2H