BESS comparison
HyperStrong HyperBlock M (AC version) vs ZOE Energy Storage Z BOX-P 6200 2H
Both columns come from what HyperStrong and ZOE Energy Storage publish. Fields either maker does not publish are marked «not published»; we do not estimate or rank.
HyperStrong
HyperBlock M (AC version)
12.8 MWh
modular blockliquid-cooledLFPshipping
ZOE Energy Storage
Z BOX-P 6200 2H
6.25 MWh
20 ft containerliquid-cooledLFPshipping
Specifications side by side
| Field | HyperStrong HyperBlock M (AC version) | ZOE Energy Storage Z BOX-P 6200 2H |
|---|---|---|
| Max energy per enclosure | 12.8 MWh | 6.25 MWh |
| Max power per enclosure | 3.2 MW | not published |
| Published durations | 4 h | 2 h |
| Segment | utility-scale | utility-scale |
| Status | shipping | shipping |
| Cell chemistry | LFP | LFP |
| Cell capacity | 601 Ah | 587 Ah |
| Cell configuration | 8P416S / 16P416S | 416S8P |
| Cell supplier | not published | not published |
| Form factor | modular block | 20 ft container |
| Block type | AC block (PCS integrated) | DC block |
| PCS integrated | yes | no |
| DC voltage | 1123.2–1497.6 (rated 1331.2) V | 1081.6–1497.6 V |
| Cooling | liquid-cooled | liquid-cooled |
| Ingress protection | Container IP55, Pack IP65, PDU IP55 | IP55 |
| Operating temperature | -30…55 °C | -30…55 (>45 derating) °C |
| Dimensions (L × W × H) | 6058 × 2438 × 2896 mm | 6058 × 2438 × 2896 mm |
| Weight | 24 t | 48 t |
| Energy density | not published | not published |
| Round-trip efficiency | 93% | not published |
| Cycle life | 10,000 · >10000cls@SOH70%, 0.5P, to achieve up to 20 years of operation life guarantee | not published |
| Calendar life | 20 y | not published |
| Warranty | not published | not published |
| Fire suppression | Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection | aerosol-based suppression; flooded fire protection option; pack-level fire protection |
| Generation | MagicBlock platform, 2025 | not published |
| Announced | 2025-05 | not published |
| Certifications | EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120 | IEC 61000, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL 9540A, UN 3536, UN 38.3 |
| Public datasheet | yes | yes |
Where they differ
Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.
- Max energy per enclosure: HyperBlock M (AC version) — 12.8 MWh; Z BOX-P 6200 2H — 6.25 MWh
- Published durations: HyperBlock M (AC version) — 4 h; Z BOX-P 6200 2H — 2 h
- Cell capacity: HyperBlock M (AC version) — 601 Ah; Z BOX-P 6200 2H — 587 Ah
- Cell configuration: HyperBlock M (AC version) — 8P416S / 16P416S; Z BOX-P 6200 2H — 416S8P
- Form factor: HyperBlock M (AC version) — modular block; Z BOX-P 6200 2H — 20 ft container
- Block type: HyperBlock M (AC version) — AC block (PCS integrated); Z BOX-P 6200 2H — DC block
- PCS integrated: HyperBlock M (AC version) — yes; Z BOX-P 6200 2H — no
- DC voltage: HyperBlock M (AC version) — 1123.2–1497.6 (rated 1331.2) V; Z BOX-P 6200 2H — 1081.6–1497.6 V
- Ingress protection: HyperBlock M (AC version) — Container IP55, Pack IP65, PDU IP55; Z BOX-P 6200 2H — IP55
- Operating temperature: HyperBlock M (AC version) — -30…55 °C; Z BOX-P 6200 2H — -30…55 (>45 derating) °C
- Weight: HyperBlock M (AC version) — 24 t; Z BOX-P 6200 2H — 48 t
- Fire suppression: HyperBlock M (AC version) — Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection; Z BOX-P 6200 2H — aerosol-based suppression; flooded fire protection option; pack-level fire protection
- Certifications: HyperBlock M (AC version) — EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120; Z BOX-P 6200 2H — IEC 61000, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL 9540A, UN 3536, UN 38.3
Published by only one of the two: Max power per enclosure, Round-trip efficiency, Cycle life, Calendar life, Generation, Announced.
Variants
HyperStrong HyperBlock M (AC version) variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| HSL3G71-06400 — 6.4 MWh / 400 kW×4 | 6.4 MWh | 1.6 MW | 4 h |
| HSL3G71-12800 — 12.8 MWh / 400 kW×8 | 12.8 MWh | 3.2 MW | 4 h |
ZOE Energy Storage Z BOX-P 6200 2H variants
| Variants | Energy | Power | Duration |
|---|---|---|---|
| P 6200-2H (6.25 MWh, '2H~8H' long-duration) | 6.25 MWh | not published | 2 h |
Full model cards
Open HyperStrong HyperBlock M (AC version) →Open ZOE Energy Storage Z BOX-P 6200 2H →
Other comparisons
Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs ZOE Energy Storage Z BOX-P 6200 2HGotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs HyperStrong HyperBlock M (AC version)Pylontech Container L5000-BAT vs ZOE Energy Storage Z BOX-P 6200 2HPylontech Container L5000-BAT vs HyperStrong HyperBlock M (AC version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs ZOE Energy Storage Z BOX-P 6200 2HSunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs HyperStrong HyperBlock M (AC version)CATL TENER vs ZOE Energy Storage Z BOX-P 6200 2HCATL TENER vs HyperStrong HyperBlock M (AC version)