FieldHyperStrong HyperBlock M (AC version)Trina Storage Elementa 2
Max energy per enclosure12.8 MWh5.015 MWh
Max power per enclosure3.2 MWnot published
Published durations4 hnot published
Segmentutility-scaleutility-scale
Statusshippingshipping
Cell chemistryLFPLFP
Cell capacity601 Ah314 Ah
Cell configuration8P416S / 16P416S1P416S12P
Cell suppliernot publishednot published
Form factormodular block20 ft container
Block typeAC block (PCS integrated)DC block
PCS integratedyesno
DC voltage1123.2–1497.6 (rated 1331.2) V1123.2–1497.6 V
Coolingliquid-cooledliquid-cooled
Ingress protectionContainer IP55, Pack IP65, PDU IP55IP55 (container, excl. TMS); IP67 module
Operating temperature-30…55 °C-30…50 °C
Dimensions (L × W × H)6058 × 2438 × 2896 mm6058 × 2438 × 2896 mm
Weight24 t42.5 t
Energy densitynot publishednot published
Round-trip efficiency93%not published
Cycle life10,000 · >10000cls@SOH70%, 0.5P, to achieve up to 20 years of operation life guarantee10,000 · Datasheet claim: 'up to 10,000 cycles with 0 degradation in first half year'; test conditions not published
Calendar life20 ynot published
Warrantynot publishednot published
Fire suppressionCombustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protectionautomatic aerosol-based fire suppression system; water-based suppression optional; heat/smoke/gas sensors, active ventilation
GenerationMagicBlock platform, 20252
Announced2025-05not published
CertificationsEN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120CE, IEC 61000-6-2/4, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL 1973, UL 9540, UL 9540A, UN38.3
Public datasheetyesyes

Where they differ

Only fields both manufacturers publish and where the values are not identical. Not a judgement — the right choice depends on the project.

  • Max energy per enclosure: HyperBlock M (AC version) — 12.8 MWh; Elementa 2 — 5.015 MWh
  • Cell capacity: HyperBlock M (AC version) — 601 Ah; Elementa 2 — 314 Ah
  • Cell configuration: HyperBlock M (AC version) — 8P416S / 16P416S; Elementa 2 — 1P416S12P
  • Form factor: HyperBlock M (AC version) — modular block; Elementa 2 — 20 ft container
  • Block type: HyperBlock M (AC version) — AC block (PCS integrated); Elementa 2 — DC block
  • PCS integrated: HyperBlock M (AC version) — yes; Elementa 2 — no
  • DC voltage: HyperBlock M (AC version) — 1123.2–1497.6 (rated 1331.2) V; Elementa 2 — 1123.2–1497.6 V
  • Ingress protection: HyperBlock M (AC version) — Container IP55, Pack IP65, PDU IP55; Elementa 2 — IP55 (container, excl. TMS); IP67 module
  • Operating temperature: HyperBlock M (AC version) — -30…55 °C; Elementa 2 — -30…50 °C
  • Weight: HyperBlock M (AC version) — 24 t; Elementa 2 — 42.5 t
  • Cycle life: HyperBlock M (AC version) — 10,000 · >10000cls@SOH70%, 0.5P, to achieve up to 20 years of operation life guarantee; Elementa 2 — 10,000 · Datasheet claim: 'up to 10,000 cycles with 0 degradation in first half year'; test conditions not published
  • Fire suppression: HyperBlock M (AC version) — Combustible gas detection, temperature sensor, smoke detection, cabin level aerosols, deflagration venting panels, water fire protection; Elementa 2 — automatic aerosol-based fire suppression system; water-based suppression optional; heat/smoke/gas sensors, active ventilation
  • Generation: HyperBlock M (AC version) — MagicBlock platform, 2025; Elementa 2 — 2
  • Certifications: HyperBlock M (AC version) — EN50549, EN61000, G99, IEC60730, IEC62477, IEC62619, IEC62933, IEEE1547, NFPA855/68/69, UL1741, UL1973, UL9540, UL9540A, UN38.3, VDE4110, VDE4120; Elementa 2 — CE, IEC 61000-6-2/4, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, UL 1973, UL 9540, UL 9540A, UN38.3

Published by only one of the two: Max power per enclosure, Published durations, Round-trip efficiency, Calendar life, Announced.

Variants

HyperStrong HyperBlock M (AC version) variants

VariantsEnergyPowerDuration
HSL3G71-06400 — 6.4 MWh / 400 kW×46.4 MWh1.6 MW4 h
HSL3G71-12800 — 12.8 MWh / 400 kW×812.8 MWh3.2 MW4 h

Trina Storage Elementa 2 variants

VariantsEnergyPowerDuration
5.015 MWh (314 Ah, 12 racks × 4 modules), 2–4 h5.015 MWhnot publishednot published
4.073 MWh (306 Ah, 1P416S10P, 10 racks × 4 packs), 2–6 h4.073 MWhnot publishednot published

Full model cards

Open HyperStrong HyperBlock M (AC version) →Open Trina Storage Elementa 2 →

Other comparisons

Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs HyperStrong HyperBlock M (AC version)Gotion High-Tech Gotion Grid 5 MWh (ESD1331-05P5015) vs Trina Storage Elementa 2Pylontech Container L5000-BAT vs HyperStrong HyperBlock M (AC version)Pylontech Container L5000-BAT vs Trina Storage Elementa 2Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs HyperStrong HyperBlock M (AC version)Sunwoda Energy NoahX 2.0 (NoahX-1500/4170, NoahX-1500/5015-L2) vs Trina Storage Elementa 2CATL TENER vs HyperStrong HyperBlock M (AC version)CATL TENER vs Trina Storage Elementa 2